摘要
针对给排水管道穿越隔震建筑的隔震层(沟)应设置柔性连接的要求,对不同的隔震建筑类型中给排水管道系统的受力及位移情况展开分析和研究,给出了不同条件下柔性连接节点的设置要求和计算方法。
In view of the requirement of flexible connection for water plumbing pipeline to cross the isolation layer(ditch) of seismic isolated building, the force and displacement of water plumbing pipeline system in different seismic isolated building types are analyzed and studied, and the setting requirements and calculation methods of flexible connection nodes under different conditions are given.