摘要
通过FIRE软件对某汽油机冷却水套进行计算流体动力学(computational fluid dynamic,CFD)分析计算,得到了水套的速度场分布和温度场分布结果,发现冷却水套存在局部区域流速过低、温度梯度过大等问题。针对问题提出了3种优化方案:优化水套结构、改进外部水泵结构、及两者的结合。对3种方案进行计算分析,结果表明,采用第3种优化方案,冷却效果好。
The computational fluid dynamic( CFD) simulation of a gasoline engine cooling jacket model was done using the FIRE software,and the velocity and temperature distributions of the water jacket were obtained,revealing the problems of low local flow rate and high temperature gradient. Three optimization solutions to the problems were proposed: cooling jacket structure optimization,water pump improvement and the combination of both. A good cooling effectiveness was achieved by the third solution.
引文
[1]董春波,陈群,李金成.分体冷却式柴油机缸盖水套的CFD分析[J].汽车技术,2004(3):9-12.
[2]王书义,王宪成,段初华,等.发动机冷却水流动三维数值模拟基础研究[J].内燃机学报,1994,12(1):57-63.
[3] SHIH S,ITANO E,XIN J,et al. Engine knock toughness improvement through water jacket optimization[C]. SAE International,2003-01-3259.
[4] MAKKAPATI S,POE S,SHAIKH Z,et al.Coolant velocity corrections in an IC engine coolant jacket[C]. SAE International,2002-01-1203.
[5] YE J,COVEY J,AGNEW D. Coolant flow optimization in a racing cylinder block and head using CFD analysis and testing[C]. SAE International,2004-01-3542.
[6]杨攀,许涛,阮仁宇,等.某发动机冷却水套优化设计[J].内燃机与动力装置,2014(03):40-42.