能谱CT单能量成像评价冠状动脉非钙化性斑块的临床应用
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Clinical application of spectral CT single spectral imaging in the coronary artery of non calcified plaque
  • 作者:胡玉明 ; 罗悦凡 ; 邓全越 ; 刘怀忠 ; 李杰生
  • 英文作者:Hu Yuming;Luo Yuefan;Deng Quanyue;Liu Huaizhong;Li Jiesheng;Guangdong Medical College Affiliated Sanshui Hospital;
  • 关键词:冠状血管 ; 能谱CT ; 单能量成像 ; 噪声比 ; 对比噪声比
  • 英文关键词:Coronary vessels;;Spectral CT;;Single spectral imaging;;Signal to noise ratio;;Contrast to noise ratio
  • 中文刊名:SYYJ
  • 英文刊名:Journal of Practical Medical Techniques
  • 机构:广东医学院附属三水医院;
  • 出版日期:2015-05-15
  • 出版单位:实用医技杂志
  • 年:2015
  • 期:v.22
  • 语种:中文;
  • 页:SYYJ201505006
  • 页数:4
  • CN:05
  • ISSN:14-1298/R
  • 分类号:17-20
摘要
目的评价宝石能谱CT单能量成像在冠状动脉管腔非钙化性狭窄的临床应用价值。方法对15例18段非钙化斑块所致的有意义狭窄(狭窄度≥50%)进行从40 ke V到90 ke V单光子成象,间隔5 ke V,获取18段病变血管11组单能量图像,测量每个病变区并比较每例被检者每组单能量图像的噪声值(以SD值表示)、信噪比(SNR)及对比噪声比(CNR)并选取最佳信噪比及最佳对比噪声比的图像与常规140 k Vp混合能量图像进行比较,采用配对分析法比较组间数据差异。结果 18例11组单能量成像中,随着ke V降低,噪声值逐步增高,75 ke V单能量图像平均噪声最低,70 ke V以下单能量图像噪声差异有统计学意义,70 ke V以上单能量图像噪声差异无统计学意义,75 ke V噪声最低,病变区域最高信噪比及对比噪声比集中在(65~75)ke V,其中以70 ke V组最高,分别为29±7及30±8,在信噪比中3组之间差异无统计学意义(P>0.05),在对比噪声比中70 ke V与75 ke V组间差异无统计学意义(P>0.05),而与邻组信噪比及对比噪声比差异有统计学意义(P<0.05),与混合能量图像信噪比及对比噪声比差异有统计学意义(t值分别为5.37及7.07,P<0.01)。结论能谱(65~75)ke V,单能量图像对冠状动脉非钙化性斑块信噪比及对比噪声比相对较高,65 ke V对类脂性斑块敏感性较高,在低剂量低幅射量检查中具有较高的临床价值。
        Objective To evaluate the clinical application value of single energy stones energy spectrum CT imaging in coronary artery lumen narrow of non calcified. Methods Fifteen cases of 18 period of non calcified plaque which the stenosis was significant(≥50%) were to be for single photon imaged from 40 ke V to 90 ke V,by interval 5ke V,and getting 18 paragraph lesion blood vessel 11 groups of single energy of image. By measurement of each lesion area and comparing with each case of single image values(expressed in SD value),the signal to noise ratio(SNR)and contrast to noise ratio(CNR)and selecting the best signal-to-noise ratio and the best contrast to noise ratio compared with conventional 140 k Vp hybrid energy image of data differences between paired comparison group. Results In 11 single energy imaging group of 18 cases,the noise value increased with ke V decreasing,the average noise value was lowest for75 ke V single energy image,There were significant differences in the single energy noise below 70 ke V,more than 70 ke V single noise energy difference had not significant differences,75 ke V noise was lowest,highest signal-to-noise ratio and lesion contrast SNR was concentrated in the(65-75) ke V,of which 70 ke V group is highest,(29 ±7 and 30 ±8)respectively,in the signal to noise ratio,There was no obvious difference between the three groups(P>0.05);There was no difference in contrast SNR 70 ke V and 75 ke V groups(P >0.05),and compared with adjacent group signal-to-noise ratio SNR has difference(P<0.05),compared with hybrid energy image signal-to-noise ratio signal-to-noise ratio difference is significant(t =5.37 and 7.07,P <0.01). Conclusion Spectrum(65-75) ke V,single energy image of non calcified coronary artery plaque signal-to-noise ratio and comparative signal-to-noise ratio is relatively high,65 ke V of lipid plaque sensitivity is higher,in low doses low-rising radiometric check has higher clinical value.
引文
[1]侯志辉,吕滨.冠状动脉CT成像对急性冠状动脉事件的预测价值[J].中华放射学杂志,2012,46(4):382-384.
    [2]Nieman K,Cademartiri F,Lemos PA,et al.Reliable noninvasive coronary with fasl submillimeler multislice spiral computed tomography[J].Circulation,2002,106(16):2051-2054.
    [3]Austen WG,Edwards JE,Frye RL,et al.A reporting system on patients evaluated for coronary artery disease,report of the Ad Hoc Committee for Grading of Coronary Artery Disease,Council on Cardivoascular Surgery,American Heart Association[J].Circulation,1975,51:5-40.
    [4]朱砚,祁吉.多层螺旋CT鉴别冠状动脉脂质与纤维斑块的Meta分析[J].实用放射学杂志,2012,28(9):1338-1344.
    [5]綦维维,杜湘珂,郭英.64层螺旋CT心脏成像获得一致噪声及控制辐射剂量的个体化管电流选择方法[J].中华放射学杂志,2008,42(10):1026-1028.
    [6]汪洁,王万勤,刘斌,等.体外实验中宝石CT能谱成像技术血管成像最佳单能量图像的选举[J].中国医学影像技术,2011,27(11):2340-2343.
    [7]姬妮娜,高剑波,田辉英.能谱成像最佳对比噪声比技术对胃周动脉成像质量的影响[J].放射学实践,2013,28(1):51-54.
    [8]吕培杰.CT能谱成像在小肝癌检测中的应用价值[J].放射学实践,2011,26(3):321-324.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700