摘要
阐述了一起天然气计量异议的技术处理过程,根据天然气分离出油和水的现象查找到计量异议发生的原因,分析了天然气气体组分变化对流量测量结果的影响趋势,运用专业的标准孔板设计计算软件计算修正了计量数据,正确、公正地用技术手段解决了计量异议,并用在线比对的方式对技术手段合理性和标准孔板计量系统流量测量结果的准确性进行了验证。
The technical treatment process of a natural gas metering objection is expounded. The causes of the metering objection are found out according to the phenomenon of oil and water separating from natural gas, the influence trend of natural gas composition on the flow-rate measurement result is analyzed, the metering data are calculated and corrected by using professional standard orifice plate design software, and the metering objection is correctly and fairly solved by technical means. The rationality of the technical means and the accuracy of flow-rate measurement results of standard orifice plate metering system are verified by means of on-line comparison.
引文
[1]全国天然气标准化技术委员会.天然气取样导则:GB/T13609—2017[S].北京:中国标准出版社,2018.
[2]全国天然气标准化技术委员会.天然气压缩因子的计算第2部分:用摩尔组成进行计算:GB/T 17747.2—2011[S].北京:中国标准出版社,2012.
[3]全国天然气标准化技术委员会.天然气发热量、密度、相对密度和沃泊指数的计算方法:GB/T 11062—2014[S].北京:中国标准出版社,2015.
[4]全国石油天然气标准化技术委员会.天然气计量系统技术要求:GB/T 18603—2014[S].北京:中国标准出版社,2015.
[5]石油工业油气计量及分析方法专业标准化技术委员会.用标准孔板流量计测量天然气流量:GB/T 21446—2008[S].北京:中国标准出版社,2008.