目的探究温度与时间对尿液分析仪检测潜血与血尿测定的影响,为提高检测的准确率寻求指导依据。方法选取2016年3月~2017年3月我院门诊就诊患者留取血尿标本为研究对象,在不同室温下放置不同的时间后,用尿液分析仪和显微镜下红细胞计数,比较各组间隐血测试情况和红细胞的减少情况。结果各组间隐血测试无改变,而镜检红细胞数随时间、温度的改变逐渐减少。相同来源的样品在12~22℃条件下检测结果优于22~30℃,差异有统计学意义(P<0.05)。结论尿液标本在12~22℃室温条件下保存时建议在2 h内完成检测,若室外温度较高时,应当在1 h内完成检测。
        Objective To explore the influence of temperature and time on urine occult blood and hematuria determination by urine analyzer,so as to provide guidance for improving the accuracy of detection.Methods The hematuria was selected as the study object in the outpatient department of our hospital in March 2016 ~March 2017.After different room temperature at different room temperature,the urine analyzer and the erythrocyte count under microscope were used to compare the occult blood test and the reduction of red blood cells in each group.Results There was no change in the occult blood test among the groups,but the number of microscopic red blood cells changed gradually with time and temperature.The samples from the same source were better than 22~30 ℃ at 12~22℃,and the difference was statistically significant(P<0.05).Conclusion When urine specimens are stored at room temperature 12~22℃,it is recommended to complete the test within 2 h.If the outdoor temperature is high,the test should be completed within 1 h.
引文
[1]蔡旭君,韦建武,韩莹,等.尿潜血阳性患者2次晨尿中红细胞形态比较[J].蚌埠医学院学报,2014,39(2):257-258.
    [2]余群秀.血尿与尿潜血之差异[J].临床医药文献电子杂志,2014,1(8):1441,1444.
    [3]蔡月华,詹桂芬,温婉颜,等.临床尿液检验结果异常的临床分析[J].当代医学,2014,11(20):48,49.
    [4]郭新玲.尿潜血尿液分析仪检验法与显微镜红细胞计数检验法应用效果对比[J].中文信息,2017,6(3):284.
    [5]钱同胜,刘云,朱进华,等.刍议尿中红细胞形态分析[J].中国伤残医学,2014,8(21):138-139.
    [6]刘凤奎,陈海平.血尿临床诊断思路[J].中国临床医生杂志,2016,44(2):22-25.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700