摘要
为了实现调度端对厂站端二次设备在线监视与分析,提出建立智能变电站网络报文记录分析装置采集信息模型。模型由公共、告警、SV协议、GOOSE协议及MMS协议等逻辑设备组成。从网络报文记录分析装置采集信息的特性分析出发,研究了过程层和站控层网络信息的异常状态形成原因及特征量,将智能变电站二次设备运行状态关键信息整理和抽取,形成暂态数据交换文件和稳态数据交换文件,并上送至调度端,在二次设备可视化状态监视和智能站高级应用功能工程实用化等方面进行研究和探索。
In order to realize online supervision and analysis of secondary equipment of the plant/station end at the dispatch end, this paper proposed an information acquisition model for the network message recording and analyzing device at the smart substation, which was composed of logic devices such as public information, alarm, SV protocol, GOOSE protocol and MMS protocol. Starting from the analysis of the features of the information acquired through network message recording and analyzing devices, this paper discussed the causes of abnormal state of the network information as well as its characteristic quantity at the process level and the station level. Key information about the operating state of the secondary equipment at the smart substation was sorted out and extracted to generate transient-state data exchange file and steady-state data exchange file, which were sent up to the dispatch end. This paper conducted a study on visualized state monitoring of secondary equipment as well as practical engineering for advanced application functions of the smart substation.
引文
[1]丁修玲,张延旭,蔡泽祥,等.基于报文解析的变电站过程层网络信息流异常保护方法[J].电力系统保护与控制,2013,41(13):58-63.
[2]李峰,谢俊,赵银凤,等,基于IEC61850的智能变电站交换机IED信息模型[J].电力系统自动化,2012,36(7):76-80.
[3]王德文,邸剑,张长明.变电站状态监测IED的IEC 61850信息建模与实现[J].电力系统自动化,2012,36(3):81-86.
[4]袁浩,屈刚,庄卫金,等.电网二次设备状态监测内容探讨[J].电力系统自动化,2014,38(12):100-106.
[5]修黎明,高湛军,黄徳斌,等.智能变电站二次系统设计方法研究[J].电力系统保护与控制,2012,40(22):124-128.
[6]朱林,王鹏远,石东源.智能变电站通信网络状态监视信息模型及配置描述[J].电力系统自动化,2013,37(11):87-92.
[7]DL/T 860变电站通信网络与系统第6部分:与智能电子设备有关的变电站内通信配置描述语言[S].北京:国家发展和改革委员会,2008.
[8]崔巍,史永,孙兵.基于IEC61970/61968电网模型构建与整合[J].电力系统保护与控制,2011,39(17):60-63.
[9]胡道徐,沃建栋.基于IEC61850的智能变电站虚回路体系[J].电力系统自动化,2013,37(11):78-82.