摘要
采用X荧光光谱法(XRF)测定铀矿比对样品中的40 K,进行实验室间比对,由比对结果直方图可看出,评价满意;同时,在实验室内部与其他两种方法——高分辨率电感耦合等离子体质谱法(HR-ICP-MS)及低本底γ能谱法的检测结果比较,3种方法的结果具有很高的一致性。以上表明,XRF法测定地质样品中的40 K快速、准确、可信。
There are many methods to measure K such as gravimetric analysis,infrared spectroscopy etc.In this paper,XRF was used to determine ~(40)K in uranium ore sample and the measured result was compared between different laboratories and the evaluation histogram showed satisfied level.The XRF measured results are also compared with HR-ICP-MS and HpGeγ methods,and the three method showed high consistency.All this indicates that XRF method is quick,accurate and reliable.
引文
[1]罗立强,詹秀春,李国会.X射线荧光光谱分析[M].北京:化学工业出版社,2015.
[2]吴建之,赵宏樵.ICP-AES法同时测定大洋富钴结壳中主量元素[J].理化检验-化学手册,2000,(7):309-312.
[3]JJF1059.1-2012,测量不确定度评定与表示[S].2012:9-27.
[4]中国合格评定国家认可委员会.GNAS-GL02:2014《能力验证结果的统计处理和能力验证评价指南》[EB/OL].https://wenku.baidu.com/view/fbec5b796bd97f192379e942.html,2014-10-09/2016-12-28.
[5]王小欢,孟庆芬,董亚萍,等.X射线荧光光谱法快速分析盐湖粘土矿物元素含量[J].光谱学与光谱分析,2010,30(3):829-833.
[6]冉广芬.钾的检测方法及其应用[J].盐湖研究,2014,(3):68-72.
[7]应晓浒,曹国洲.熔融制样X射线荧光光谱法测定钠长石钾长石中多种元素[J].盐矿测试,2003,22(3):221-224.
[8]梁帮宏,李兵,孙鹏,等.环境样品中铀的HRICP-MS测定[J].化学研究与应用,2016,28(1):134-138.
[9]李燕红,杨旗风,张芬楼,等.应用小型X射线荧光光谱仪快速测定钾长石的化学成分[J].光谱实验室,2000,17(5):596-598.
[10]方震,刘耀炜,杨选辉,等.X射线荧光光谱法测定地震地球化学样品中的主微量元素[J].光谱实验室,2012,29(5):2805-2810.