黄铜管道部件应力腐蚀失效分析
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Failure Analyses of Stress Corrosion in Brass Pipe Parts
  • 作者:许雯
  • 英文作者:XU Wen;Shanghai Railway Certification Co.,Ltd.;
  • 关键词:黄铜管道 ; 应力腐蚀 ; 断裂 ; 失效分析
  • 英文关键词:brass pipe parts;;stress corrosion;;fracture;;failure analysis
  • 中文刊名:GWRC
  • 英文刊名:Heat Treatment Technology and Equipment
  • 机构:上海轨道交通检测技术有限公司;
  • 出版日期:2019-06-25
  • 出版单位:热处理技术与装备
  • 年:2019
  • 期:v.40;No.234
  • 语种:中文;
  • 页:GWRC201903024
  • 页数:7
  • CN:03
  • ISSN:36-1291/TG
  • 分类号:66-72
摘要
通过2个在一定腐蚀环境下工作的黄铜管道部件失效断裂的案例,分析黄铜管道部件的特点及失效原因,有助于提高黄铜管道的运行水平。结果表明:失效件均在承受一定应力的腐蚀环境中服役,从而引发应力腐蚀开裂。
        Through two cases of failure and fracture of brass pipe parts working in a certain corrosive environment,the characteristics and failure reasons of brass pipe parts are analyzed,which is helpful to improve the operation level of brass pipe. The results show that the failure parts are all in service in corrosive environment under certain stress conditions,so as to stress corrosion cracking.
引文
[1]任颂赞,叶俭,陈德华.金相分析原理及技术[M].上海:上海科学技术文献出版社,2013.
    [2]罗贤竟.黄铜管开裂失效分析[J].腐蚀与防护,1999,20(12):560-561.
    [3] GB/T 5231—2012加工铜及铜合金牌号和化学成分[S].
    [4]尚尔峰,王志明,王亚勤.黄铜三通接头裂纹原因分析[J].热处理技术与装备,2016,37(1):51-55.