多焦点人工晶体植入术后双眼离焦曲线对视觉功能的评价
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Evaluation of visual function after multifocal intraocular lens implantation through defocus curves assessment
  • 作者:凌宇 ; 熊飞 ; 于璐 ; 郝晓琳 ; 程杰
  • 英文作者:LING Yu;XIONG Fei;YU Lu;HAO Xiaolin;CHENG Jie;Department of Ophthalmology,Aerospace Center Hospital;
  • 关键词:多焦点 ; 人工晶体 ; 离焦曲线
  • 英文关键词:multi-focal;;IOL;;defocus curve
  • 中文刊名:SYYZ
  • 英文刊名:The Journal of Practical Medicine
  • 机构:航天中心医院眼科;
  • 出版日期:2019-05-25
  • 出版单位:实用医学杂志
  • 年:2019
  • 期:v.35
  • 基金:航天科工集团2018年医疗卫生科研项目(临床医疗类)(编号:2018-LCYL-006)
  • 语种:中文;
  • 页:SYYZ201910023
  • 页数:4
  • CN:10
  • ISSN:44-1193/R
  • 分类号:115-118
摘要
目的利用离焦曲线评价观察多焦点人工晶体植入术后患者的真实生活视力。方法回顾性分析2017年5月至2018年5月间收治的老年性白内障患者60例(120眼),按植入晶体不同分为两组,各30例(60眼)。其中植入ZEISS AT LISA 809M晶体者30例(60眼)设为多焦非球面组(观察组),植入HOYA-PY60AD晶体者30例(60眼)设为单焦非球面组(对照组),术后3个月观察术眼的屈光状态、双眼离焦曲线、脱镜率并问卷调查视觉质量。结果术前两组患者远视力及最佳矫正近视力情况差异无统计学意义(P> 0.05),术后观察组的裸眼近视力(UCNVA)明显优于对照组(P <0.01);离焦曲线测量显示:观察组曲线下面积大于对照组,近距离曲线呈平滑趋势,而对照组的近距离曲线呈明显下降趋势,在-1.5 D(66 cm)、-3.5 D(33 cm)两点处两组视力表现差异有统计学意义(P <0.01)。结论两种晶体均可为患者提供良好的裸眼远视力;真实生活中多焦点非球面人工晶状体裸眼近视力效果更佳,脱镜率更高、视觉效果满意度更高,可为白内障患者术后提供更好的视觉质量。
        Objective To observe the visual quality after phacoemulsification combined with ZEISS AT LISA 809 M or HOYA-PY60 AD implementation by defocus curve testing. Methods This is a retrospective controlled study. 60 patients(120 eyes)with bilateral cataract were observed. 30 patients(60 eyes)in the test group were implanted bilaterally with ZEISS AT LISA 809 M IOL,and 30 patients(60 eyes)in the control group were implanted bilaterally with HOYA-PY60 AD IOL. The follow-up period was 3 months. Overall visual acuity,defocus curve testing,patient-reported outcomes were assessed. Results Binocular uncorrected near visual acuity(UCNVA)was statistically significantly better in the test group than that in the control group(P < 0.01);there was no difference in corrected near or distance visual acuity(P > 0.05). The defocus curve testing shows that the area of the defocus curve in the test group is bigger than that in the control group;the first peak position of the two groups is at 0 D to-1 D;the curve between-1.5 D and-3.0 D was smooth;and visual acuity at-1.5 D(66 cm)and-3.5 D(33 cm)were statistically significantly better in the test group. In the questionnaire,the rate of satisfaction of neardistance and off-glass in the test group were higher than that in the control group(P < 0.01). Conclusion Both intraocular lens(IOL)can obtain good near and far visual acuity. The AT LISA tri 839 MP IOL can obtain better intermediate visual acuity and higher patient satisfaction,and has better full-time visual acuity.
引文
[1] SHAH S,PERIS-MARTINEZ C,REINHARD T,et al. Visual outcomes after cataract surgery:Multifocal versus monofocal intraocular lenses[J]. J Refract Surg,2015,31(10):658-666.
    [2] MCNEELY RN,PAZO E,SPENCE A,et al. Visual quality and performance comparison between 2 refractive rotationally asymmetric multifocal intraocular lenses[J]. J Cataract Refract Surg,2017,43(8):1020-1026.
    [3] MCNEELY R N,PAZO E,SPENCE A,et al. Comparison of the visual performance and quality of vision with combined symmetrical inferonasal near addition versus inferonasal and superotemporal placement of rotationally asymmetric refractive multifocal intraocular lenses[J]. J Cataract Refract Surg,2016,42(12):1721-1729.
    [4] SACHDEV G S,RAMAMURTHY S,SHARMA U,et al. Visual outcomes of patients bilaterally implanted with the extended range of vision intraocular lens:A prospective study[J]. Indian J Ophthalmol,2018,66(3):407.
    [5] MAURINO V,ALLAN B D,RUBIN G S,et al. Quality of vision after bilateral multifocal intraocular lens implantation:a randomized trial-AT LISA 809M versus AcrySof ReSTOR SN6AD1[J].Ophthalmology,2015,122(4):700-710.
    [6] PLAZA-PUCHE A B,ALIO J L. Analysis of defocus curves of different modern multifocal int-raocular lenses[J]. Eur J Ophthalmol,2016,26:412-417.
    [7] BRITO P,SALGADO-BORGES J,NEVES H,et al. Light-distortion analysis as a possible indicator of visual quality after refractive lens exchange with diffractive multifocalintraocular lenses[J]. J Cataract Refract Surg,2015,41(3):613-622.
    [8]余萍,王青,刘玲玲.多焦点人工晶体治疗老年性白内障的安全性和有效性:随机对照临床试验方案[J].中国组织工程研究,2016,20(47):7139-7144.
    [9]林志博,黄芳潘,安鹏,等.区域折射型多焦点人工晶状体植入术后视觉质量的临床研究[J].中华眼视光学与视觉科学杂志,2017,19(8):482-487.
    [10]陈琛、屈思萌,韦秋红,等.区域折射型多焦点人工晶状体SBL-3植入前后白内障患者视觉质量的变化分析[J].中国保健医学杂志2018,20(6):488-491.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700