摘要
介绍尼日尔GANARAM北部水源地供给津德尔市饮用水系统扩建工程案例,分析泵站地基处理施工中地下水位变化的危害,进而选择合理的措施来控制地下水位以及布置施工方案。
How to effectively control the groundwater table in the foundation treatment of pump station is an important issue that our country pays attention to. It needs the relevant departments and individuals to attach great importance. This article mainly introduces the case of drinking water system expansion in Zinder City, north of GANARAM water source in Niger, and analyzes the hazard of groundwater level change during the foundation treatment of pumping station, and then chooses reasonable measures to control the water table and arrange the construction plan.
引文
[1]高绪龙,王更贵.浅析泵站施工质量控制[J].城市建设理论研究(电子版),2014(7).
[2]李凤兰,陈文彪.白坭泵站主泵房深基坑开挖工程的探讨[J].中国水利,2003(8):61-62.
[3]梅瑞松,杨富昌.我国泵站工程的现状与发展[J].水利水电科技进展,2000(1):21-23.
[4]张胜.泵站水位控制系统的改造[J].佛山科学技术学院学报(自然科学版),2016(4):44-47.
[5]王岩,任福燕.排水泵站水位控制的依据和改进[J].天津市政设计,2002(2):12-15.
[6]杨林.泵站地基处理施工中地下水位的控制[J].中国标准化,2017(10):200.
[7]马南湘,马骏.复杂条件下深基坑沉箱止水井点降水施工技术[J].建筑技术,2017,48(3):243-244.