电能表接插件优化设计
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Optimal Design of Connectors for Electric Energy Meter
  • 作者:穆小星 ; 陈刚 ; 徐敏锐 ; 金萍 ; 欧阳曾恺
  • 英文作者:MU Xiaoxing;CHEN Gang;XU Minrui;JIN Ping;OUYANG Zengkai;Jiangsu Electrical Power Company Research Institute,State Grid;Key Laboratory of Electrical Power Metering,State Grid;
  • 关键词:电能表 ; 接插件 ; 接触电阻 ; 最大插入力 ; 分离力 ; 接插件插头 ; 接插件支架 ; 温升
  • 英文关键词:Electric energy meter;;Connector;;Contact resistance;;Maximum plug-in force;;Pull-out force;;Connector plug;;Connector bracket;;Temperature rise
  • 中文刊名:ZDYB
  • 英文刊名:Process Automation Instrumentation
  • 机构:国网江苏省电力公司电力科学研究院;国家电网公司电能计量重点实验室;
  • 出版日期:2019-05-20
  • 出版单位:自动化仪表
  • 年:2019
  • 期:v.40;No.453
  • 基金:2017年国家电网公司科技基金资助项目(5210EF17001M)
  • 语种:中文;
  • 页:ZDYB201905004
  • 页数:8
  • CN:05
  • ISSN:31-1501/TH
  • 分类号:22-28+34
摘要
为解决人工现场电能表安装接线不可靠引发电气故障及效率低等问题,在不改变电能表目前结构的基础上,设计一种电能表电气连接专用接插件,完成电能表不上螺丝的插拔式安装。通过对接插件插拔力结构因素及参数进行系统的仿真分析,对接插件插头进行优化设计,同时满足电气性能与适用性需求。通过一系列试验及现场应用,验证了新型电能表接插件的设计正确性,实现了电能表即插即用的目标。该电能表不仅提高了电能表安装效率,同时降低了电能表运行故障率、电气安全事故的发生率,也为电力企业创造了显著经济效益。随着电能表接插件的广泛应用,通过对接插件插头弹性力进行深入研究,采用新技术、新手段,不断对插头进行技术改进,进一步降低插拔力、提高电接触性能,将使接插件在现场操作更加省力、轻松、安装快捷,电能表工作将会更加安全、可靠。
        In order to solve the problems of electrical failure and low efficiency caused by manual unreliable on-site installation and wiring of electric energy meter,on the basis of not changing the current structure of the electric energy meter,a dedicated connector for electrical connection of electric energy meter is designed,and the plug-in and pull-out installation of electric energy meter without screw is completed.The structural factors and parameters of plug-in and pull-out forces of the connector are simulated and analyzed systematically.The plug of the connector is optimized to meet the requirements of electrical performance and applicability.Through a series of tests and field applications,the design correctness of the new energy meter connector is verified,and the plug-and-play goal of electric energy meter is realized.It not only improves the installation efficiency,but also reduces the operation failure rate of electric energy meter and the occurrence rate of electrical safety accidents,and creates remarkable economic benefits for power enterprises.With the wide application of the electric energy meter connector,through in-depth study on elastic force for the plug of the connector,continuous technical improvement of the plug with new technology and new means will further reduce the insertion force and improve the electrical contact performance,which will make on-site operation of the connector more labor-saving,easy,and quick to install,the work of electric energy meter will be safer and more reliable.
引文
[1] 寇英刚,范洁,杨世海,等.一种基于实际工况的数字化电能表校验方法及其误差分析[J].电力工程技术,2017,36(6):53- 57.
    [2] 田正其,徐晴,金萍,等.基于加速退化试验数据的智能电能表早期失效分析[J].电力工程技术,2017,36(1):98- 101+112.
    [3] 翟锦奎,张志,李晓红,等.单相电能表现场快速接线方式的研究及应用[J].电测与仪表,2015(19) :67- 73.
    [4] 许军,李坤.电接触的接触电阻研究[J].电工材料,2011(1):10- 13.
    [5] 陈森昌,迟彦惠,张平.电接触现象和接触电阻模型的研究进展[J].广东技术师范学院学报,2015(2) :40- 41.
    [6] 潘骏,靳方建,陈文华.电连接器接触件结构分析与插拔试验[J].中国机械工程,2013(12):1636- 1641.
    [7] 刘新建.电连接器电接触可靠性分析研究[D].武汉:华中科技大学,2016.
    [8] 赵春颖,温晓兰,李一.电连接器的机械寿命浅析机电元件.电气应用[J] ,2014(4):28- 30.
    [9] 贺占蜀,张远西,王培卓,等.电连接器接触件的插拔和温升特性[J].华南理工大学学报(自然科学版),2017(4):59- 65.
    [10]骆燕燕,王振,李晓宁,等.电连接器热循环加速试验与失效分析研究[J] .兵工学报,2014(11):1908- 1931.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700