摘要
近年来,根据国家及上海出台的环保政策、法律法规的要求,非甲烷总烃在线装置,开始被普遍安装应用。论文针对已安装的"固定污染源非甲烷总烃连续排放系统"与手工测试比对,考察固定污染源的自动检测和手工测试结果的差异,寻找差异原因。
In recent years, according to the requirements of environmental protection policies, laws and regulations issued by China and Shanghai, non-methane total hydrocarbon online devices have been widely installed and applied. This paper compares the installed "continuous non-methane total hydrocarbon emission system of fixed pollution sources" with the manual test, examines the difference between the automatic and manual test results of fixed pollution sources, and seeks for the reasons for the difference.
引文
[1]环办环监[2018]25.关于加强重点排污单位自动监控建设工作的通知[Z].
[2]沪环保总[2018]231.上海市固定污染源挥发性有机物在线监测体系建设方案[Z].
[3]沪环保总[2016]171.上海市固定污染源非甲烷总烃在线监测系统验收及运行技术要求(试行)[Z].