摘要
压力脉冲试验适用于渗透率较低的岩层水文地质求参,通过压力脉冲试验,对水源地承压含水层隔水顶板渗透性能进行测试,从而达到评价水源地防污性能的目的。该方法较室内水理性质试验更符合现场实际情况,试验效果良好。
Pressure pulse test is suitable for hydrogeological parameters of rock strata with low permeability.Through pressure pulse test,the permeability of confined aquifer roof in water source area is tested,so as to evalate the anti-fouling performance of the water source area.Compared with indoor water property test,this method is more in line with the actural situation in the field,and the test effect is good.This work has a good guiding role for the development of similar projects,and has a certain reference value for evaluating the hydrogeological parameters of rock strata with low permeability and the evaluation of anti-fouling performance of confined aquifers.
引文
[1]中华人民共和国水利部.SL31-2003水利水电工程钻孔压水试验规程[S].北京:中国水利水电出版社,2003.
[2]陈群策,祁英男,毛吉震,等.利用压力脉冲试验测定某地花岗岩体的渗透系数[J].岩土力学,2005,26(9):1469-1472.
[3]王树理,赵显山,杨晓军,等.地下原油储备库综合水文地质勘察方法[J].勘察科学技术,2008,(2):11-14.
[4]刘兆福,翁玉武.吉林油田二龙、新村水源水文地质特性与资源保护[J].油气田地面工程,2003,22(9):32.
[5]李立军.松原市地下水防污性能评价[J].吉林地质,2008,27(2):110-113.
[6]孙政,田作印,杨晓晗.高压压水试验在蒲石河抽水蓄能电站中的应用[C]//2009年抽水蓄能学术年会论文集.北京:中国水力发电工程学会电网调峰与抽水蓄能专业委员会,2009:326-328.