本文主要对在变电站建设过程中的GIS在线监测配置策略进行分析,提出合理有效的应用建议,为变电站及特高压站GIS设备能够安全可靠运行提供保障,也为后续高寒环境下建设特高压工程GIS在线监测应用策略提供一些参考。
This paper mainly analyses and compares the strategies of on-line monitoring and configuration of GIS in the process of substation construction,and puts forward reasonable and effective application suggestions,which can guarantee the safe and reliable operation of GIS equipment in substation and UHV station,and also provide some references for online monitoring application strategy of the subsequent construction of UHV projects under the conditions of high-cold environment.
引文
[1]杨启洪,张东进,周良才.变电站绝缘在线监测技术的研究与应用[J].广东电力,2002(06):15-19.
[2]常勇,谢佳妮,张雍赟.特高压变电站在线监测系统的实践与分析[J].电力建设,2012,33(2):84-87.
[3]刘颖,郭小凯,方义治,等.GIS特高频局放在线监测技术的应用[J].高压电器,2013,49(5):128-133.
[4]孙曙光,陆俭国,俞慧忠,等.基于超高频法的典型GIS局部放电检测[J].高压电器,2012,48(4):7-12.