游泳池式反应堆全厂断电事故分析
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Analysis of SBO Accident for a Swimming Pool Reactor
  • 作者:王桂敏 ; 李炜炜 ; 李宁 ; 郭文慧
  • 英文作者:WANG Gui-min;LI Wei-wei;LI Ning;GUO Wen-hui;Nuclear and Radiation Safety Center,Ministry of Environmental Protection;China Institute of Atomic Energy;Northern Regional Office of Nuclear and Radiation Safety Inspection,Ministry of Environmental Protection;
  • 关键词:RELAP5 ; 游泳池式反应堆 ; 全厂断电 ; 自然循环
  • 英文关键词:RELAP5;;swimming pool reactor;;SBO;;natural circulation
  • 中文刊名:YZJS
  • 英文刊名:Atomic Energy Science and Technology
  • 机构:环境保护部核与辐射安全中心;中国原子能科学研究院;环境保护部华北核与辐射安全监督站;
  • 出版日期:2015-05-20
  • 出版单位:原子能科学技术
  • 年:2015
  • 期:v.49
  • 语种:中文;
  • 页:YZJS201505016
  • 页数:5
  • CN:05
  • ISSN:11-2044/TL
  • 分类号:95-99
摘要
采用RELAP5/MOD3.3程序对某游泳池式反应堆的全厂断电事故工况进行计算,对堆内冷却剂流动逆转过程进行了模拟计算,并对全厂断电事故下堆芯漏流和组件间流动等相关参数对流动逆转的影响进行了深入分析。结果表明,该反应堆在失去全部强迫流动的情况下,能形成足够的自然循环流量,以导出堆芯余热,燃料组件不会发生破损。
        The RELAP5/MOD3.3code was adopted to compute the SBO accident condition of a swimming pool reactor.The coolant flow reversal process was calculated,and the influence of parameters of the flow between the core leakage and components on the flow reversal in the SBO accident condition was analyzed.The calculated results show that in the situation the reactor loses all forced flow,the residual heat of the reactor can be removed by the natural circulation flow,and the fuel subassembly will not be damaged.
引文
[1]徐珍,杨燕华,林萌,等.反应堆热工分析程序中可视化建模技术应用[J].核动力工程,2006,27(6):38-41.XU Zhen,YANG Yanhua,LIN Meng,et al.Application of visual modelization technology to reactor thermohydraulics analysis programmes[J].Nuclear Power Engineering,2006,27(6):38-41(in Chinese).
    [2]储绍初.49-2游泳池反应堆最终安全分析报告[R].北京:中国原子能科学研究院,2011.
    [3]谢仲生,尹邦华.核反应堆物理分析[M].北京:原子能出版社,1994.
    [4]BERGLES A E.Two-phase flow and heat transfer in the power and process industries[M].London:Hemisphere Publishing Corporation,1981.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700