比较超声和MRI评估正常胎儿胸廓发育
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Comparison of ultrasonography and MRI in evaluating normal fetal thoracic development
  • 作者:连细华 ; 吕国荣 ; 黄芳
  • 英文作者:LIAN Xihua;LYU Guorong;HUANG Fang;Department of Ultrasound,the Second Affiliated Hospital of Fujian Medical University;Fujian Quanzhou Medical College,Collaborative Innovation Center for Maternal and Infant Health Service Application Technology;Department of Radiology,the Second Affiliated Hospital of Fujian Medical University;
  • 关键词:胎儿 ; 胸部 ; 超声检查 ; 磁共振成像 ; 可行性研究
  • 英文关键词:fetus;;thorax;;ultrasonography;;magnetic resonance imaging;;feasibility studies
  • 中文刊名:ZYXX
  • 英文刊名:Chinese Journal of Medical Imaging Technology
  • 机构:福建医科大学附属第二医院超声科;福建省泉州医学高等专科学校母婴健康服务应用技术协同创新中心;福建医科大学附属第二医院放射科;
  • 出版日期:2019-05-20
  • 出版单位:中国医学影像技术
  • 年:2019
  • 期:v.35;No.312
  • 基金:福建省卫生计生青年科研课题(2018-1-62);; 泉州市科技计划项目(2018N012S);; 福建省泉州医学高等专科学校母婴健康服务应用技术协同创新中心基金(XJM1802)
  • 语种:中文;
  • 页:ZYXX201905027
  • 页数:5
  • CN:05
  • ISSN:11-1881/R
  • 分类号:85-89
摘要
目的比较超声和MRI评估正常胎儿胸廓发育的可重复性和一致性。方法选取30胎正常胎儿,分别以超声和MRI测量胎儿胸廓横径、前后径、面积、胸围、胸廓体积和肺体积,采用组内相关系数(ICC)及Bland-Altman图分析同一医师及不同医师间测量结果的可重复性和一致性,以Pearson相关分析观察超声测量胎儿肺体积、胸廓体积与MRI测量值的相关性。结果同一医师及不同医师以超声测量胎儿胸廓二维指标的可重复性和一致性均高于MRI,而以MRI测量胎儿胸廓体积和肺体积的可重复性和一致性均高于超声;同一医师以超声测量胎儿胸廓横径的可重复性最高[ICC=0.996 4,95%CI(0.992 5,0.998 3)],且一致性最高[界限宽度-0.004 7±0.057 3,95%CI(-0.026 1,0.016 7)]。超声与MRI测量胎儿肺体积和胸廓体积高度相关(r=0.915、0.957,P均<0.001)。结论超声和MR均可评估正常胎儿胸廓发育,胎儿胸廓发育的二维指标测量超声优于MRI;三维指标测量MRI优于超声,但两者相关性高。
        Objective To compare the repeatability and consistency of ultrasound and MRI in evaluating normal fetal thoracic development. Methods Thirty normal fetuses were selected. The thoracic transverse diameter, anteroposterior diameter, area, circumference, volume and lung volume of fetuses were measured with ultrasonography and MRI. The repeatability and consistency of the measurement results of the same physician and different physicians were analyzed by using intraclass correlation coefficient(ICC) and Bland-Altman, and the correlation of ultrasound and MRI in measuring the lung and thoracic volume was analyzed with Pearson correlation analysis. Results The inter-/intra-physicians repeatability and consistency of fetal thorax of 2 D ultrasound measurement were higher than those of MRI, while the intra-/inter-operator repeatability and consistency of fetal thoracic volume and lung volume measured with MRI were higher than those with ultrasound. The inter-physicians reproducibility and consistency of ultrasound in measuring fetal thoracic transverse diameter were the highest(ICC=0.996 4, 95%CI [0.992 5, 0.998 3]), boundary width=-0.004 7±0.057 3, 95%CI [-0.026 1, 0.016 7]). The fetal lung volume and thoracic volume measured with ultrasound were correlated with MRI(r=0.915, 0.957, both P<0.001). Conclusion Ultrasonography and MRI are feasible in evaluating normal fetal thoracic development. Ultrasonography is superior to MRI in measuring 2 D indexes of fetal thoracic development, while MRI is superior to ultrasound in measuring 3 D indexes of fetal thoracic development, but the results have high correlation.
引文
[1] 李胜利.胎儿畸形产前超声诊断学.北京:人民军医出版社,2014:233-256,338-351.
    [2] Hubbard AM.Magnetic resonance imaging of fetal thoracic abnormalities.Top Magn Reson Imaging,2001,12(1):18-24.
    [3] Meyers ML,Garcia JR,Blough KL,et al.Fetal lung volumes by MRI:Normal weekly values from 18 through 38 weeks' gestation.AJR Am J Roentgenol,2018,211(2):432-438.
    [4] Kul S,Korkmaz HA,Cansu A,et al.Contribution of MRI to ultrasound in the diagnosis of fetal anomalies.J Magn Reson Imaging,2012,35(4):882-890.
    [5] 连细华,吕国荣,徐振宏,等.三维超声VOCAL技术评估胎儿胸廓发育及其应用.中华超声影像学杂志,2017,26(5):424-428.
    [6] 陈骊珠,王晓光,蔡爱露,等.三维超声体积自动测量技术对胎儿肺体积的研究.中国临床医学影像杂志,2012,23(7):480-483.
    [7] 凌乐文,吕国荣,苏珊珊,等.三维超声测量胎儿肺体积及其在常见胎儿肺病变随访中的应用.中国医学影像技术,2012,28(4):739-742.
    [8] 彭洋,张皓钦,关键,等.产前MRI诊断胎儿中线处硬脑膜窦畸形.中国医学影像技术,2018,34(3):391-394.