摘要
煤矿供电系统一般包括地面变电、井下中央变电所、采取变电所三部分。采取变电所一般采用可移动式变压器将中央变电所的6~10 kV电压变为0.4~3.3 kV电压,供给井下大型设备使用。对井下移动变压器的常见故障进行分析和研究,以STM32作为控制核心,设计故障检测与诊断硬件系统,利用CAN总线通讯,实现数据远程传输。
The coal mine power supply system generally consists of three parts: ground substation, underground central substation, and substation.The substation will generally use a movable transformer to convert the 6~10 KV voltage of the central substation to 0.4~3.3 KV, which will be used by large underground equipment. The common faults of underground mobile transformers were analyzed and studied. STM32 was used as the control core to design the fault detection and diagnosis hardware system, and CAN bus communication was used to realize remote data transmission.
引文
[1]王崇林,邹有明.供电技术[M].北京:煤炭工业出版社,1997.
[2]国栋.基于PLC控制的3.3 kV移动变电站测控系统的研究[D].太原:太原理工大学,2005.
[3]陈化钢,潘金蜜,吴跃华.高低压开关电器故障诊断与处理[M].中国水利水电出版社,2000.2.
[4]肖登明.电力设备在线监测与故障诊断[M].上海:上海交通大学出版社,2005.
[5]崔景岳.煤矿供电[M].北京:煤炭工业出版社,1988.
[6]胡天禄.矿井电网的漏电保护[M].北京:煤炭工业出版社,1987.
[7]宋建成.矿井低压电网选择性漏电保护性能的改进方法[J].继电器,1998,26(5):34-39.
[8]梁沛然,杨艳,达峰.一种基于煤矿智能变电站的防越级跳闸保护方案[J].煤矿机电,2013(4):67-71.