摘要
简述了引压管路在压力测试中的应用,并对引压管路动态特性进行了理论分析,研究了温度对引压管路幅频特性的影响。在不同温度下用正弦动态压力校准装置对带引压管路的压力测量系统进行扫频试验,验证了温度变化对带引压管路压力测量系统动态特性的影响。
The paper presents the application of the pressure pipeline in dynamic tests,analyses the dynamic characteristics in theory and researches the influence of the temperature to the amplitude response. Using the sinusoidal dynamic calibration device,we carried on the tests of the pressure measurement system with pressure pipeline in different temperature,verified the temperature influences on the dynamic characteristics of the pressure measurement system with pressure pipeline.
引文
[1]Hjelmgren J.Dynamic Measurement of Pressure-A Literature Survey[Z].SP Swedish National Testing and Research Institute,Boras,2002.
[2]Hashemian H M.Sensor Performance Reliability[Z].I.S.A.-The Instrumentation,System,and Automation Society,Durham,2005.
[3]王维,唐磊,王棋.压力测试管道管腔效应研究[J].计测技术,2012(Z1):81-86.
[4]张训文,陈曦,朱琦,等.压力传感器管腔效应问题研究[J].测试技术学报,2002,16(s1):387-390.
[5]叶挺,梁庭,张文栋.压力测试中引压管的动态特性研究[J].中北大学学报(自然科学版),2011,32(2):222-225.
[6]杨林,王偲臣,林峰,等.基于半无限引压管效应的动态压力测量方法[J].航空动力学报,2014,29(10):2457-2463.
[7]JJG 624-2005动态压力传感器检定规程[S].北京:中国计量出版社,2005.
[8]朱明武,王宗支,梁人杰,等.动压测量[M].北京:国防工业出版社,1984.