局部式空调是仅对工作岗位人员所在空间的空气进行处理的空调系统,在局部式空调中使用可移动式送风口,可以根据需要来改变送风位置.以可移动式送风口的设计为研究对象,分析了各种不同风道的可移动风口的设计方法.对于局部空调的可移动式送风口,可以通过PLC可编程控制器对送风口进行移动定位来处理局部空气.首先由PLC编程操作输入状态指令,然后由输出信号使空调风口移动到达指定位置.最后总结了可移动式送风口局部空调具有快速调节空气、减低安装成本、节能减排等优势.
Local air-conditioning is an air-conditioning system that only deals with the air in the worker's space. Movable air outlets are used in local air-conditioning to change the position of air supply according to the need. In this paper, the design of movable air outlet is studied, and the design methods of various movable air outlets are analyzed. For the movable air outlet of local air conditioning, the PLC programmable controller can be used to locate the air outlet to deal with local air. Firstly, the input state instructions are programmed by PLC. Then, the air-conditioning tuyere is moved to the designated position by the output signal. Finally, advantages of the local air-conditioning with movable air outlet are summarized, such as fast air-conditioning, low installation cost, energy saving and emission reduction.
引文
[1] 朱立,王子彪,卢勇.空气调节技术[M].北京.高等教育出版社,2012:32.
[2] 中华人民共和国住房和城乡建设部,中华人民共和国国家质量监督检验检疫总局.民用建筑供暖通风与空气调节设计规范GB50736-2012[S].北京:中国建筑科学研究院,2012:5.
[3] 何天祺,康侍民,卢军.供暖通风与空气调节[M].重庆:重庆大学出版社,2002:133.
[4] 杨琳.空气流量传感器智能测试系统[D].武汉:武汉理工大学,2012:6.
[5] 王德显.德国工业4.0战略对中国工业发展德启示[J],税务与经济,2016(1):16-18.
[6] 孙克春.吕留根,陈进军.商场建筑负荷特性及其影响因素模拟分析[J],制冷与空调,2011(1):45-50.
[7] 唐巧玲.对暖通空调技术发展与建筑节能的几点思考[J].产业观察,2018(8):68-69.