摘要
在无通道保护方法的基础上,提出了一种适应于船舶环形配电网的电流保护加速动作的方法。该方法利用故障发生和线路一侧断路器跳闸引起的另一侧支路电流变化,和该变化所具有的时间特性来判断故障区间,来实现故障线路两端保护的相继速动。实例仿真分析验证了该方法的可行性。
This paper presents a new accelerated action method of current protection for the shipboard loop power distribution systems, which is based on the non-communication protection method. In the method, the changing of current through local relay is adopted when the fault occurs and the remote breaker of the line is triped, and the time characteristics of this changing are used to determine the fault zone, and then accelerated trip of the local break. The simulation analysis validates the feasibility of proposed protection method.
引文
[1]邰能灵,王鹏,倪明杰.大型船舶电力系统关键技术与应用[M].北京:科学出版社,2012:94-101.
[2]范啸平,王威,邰能灵,等.船舶电网电流差动保护的应用研究[J].船电技术,2012,32(2):5-7.
[3]张宁,董新洲,薄志谦,等.输电线路综合电流差动保护方案的研究[J].电力科学与技术学报,2007,22(4):16-19.
[4]Bo,Z.Q,Dong,X.Z,Caunce,B.R.J.Accelerated protection of distribution systems with tapped off loads[J].IEEE Trans,2004(151):461-468.
[5]Zhiqian Q.Bo.Adaptive non-communication protection technique for transmission lines BO Scheme 3-the accelerated opern approach.IEEE Trans.Power Deliv,2002,17(1):97–104.
[6]刘建凯,董新洲,薄志谦.有分支配电线路无通道保护研究[J].电力系统自动化,2003,27(1):37-41.