摘要
通过比较不同高效液相色谱(HPLC)方法对维生素E与辛烯基琥珀酸酐反应产物分离效果的影响,最终建立了以Dionex Kromasil C18柱为分析柱、甲醇和0.033 mol/L H3PO4(100:1,体积比)为流动相的色谱分离条件;借助高效液相色谱-大气压化学电离源质谱联用(HPLC-APCI-MS)法检测分离得到的色谱峰,通过比较它们的紫外光谱和质谱特征,确定其中两种物质为维生素E辛烯基琥珀酸酯的异构体。
The effect of high performance liquid chromatographic(HPLC) method on the separation of the reaction product of vitamin E and octenylsuccinic anhydride was compared,and then a HPLC system consisting of a Dionex Kromasil C18 column and the mobile phase of methanol and 0.033 mol/L phosphoric acid(100/1,V/V) was established.Using the combination of UV spectra and HPLC-atmospheric pressure chemical ionization(APCI)-mass spectrometric(MS) data,two substances were identified as the isomers of vitamin E octenylsuccinate.
引文
[1]宋广勋,冯光炷,李和平,等.粮油加工,2006,8:81
[2]Xu J,Zhou C W,Wang R Z,et al.CarbohydratePolymers,2012,87:2137
[3]Tesch S,Gerhards C,Schubert H.J Food Eng,2002,54(2):167
[4]Barros L,Correia D M,Ferreira I C F R,et al.FoodChem,2008,110(4):1046
[5]Yin C H,Zhang C,Gao M.Chin J Chem Eng,2011,19(1):135
[6]李军生,黄位明,秦国梅,等.食品科学,2005,26(8):29
[7]Aly Nada,Yellela SR Krishnaiah,Abdel-AzimZaghloul,et al.Med Principles Practice,2011,20:509
[8]Norouzitallab P,Farhangi M,Babapour M,et al.Aquacul Int,2009,17:207
[9]Brooks M Hybertson.J Chem Eng Data,2007,52:1123
[10]Vijay K Singh,Pankaj K Singh,Stephen Y Wise,etal.Int Immunopharm,2011,11:842
[11]Dorrelyn Patacsil,Sylvester Osayi,Anh Thu Tran,etal.Genes Nutr,2012,7:83
[12]Vijay K Singh,Darren S Brown,Tzu-Cheg Kao.IntImmunopharm,2009,9:1423
[13]Renee L Good,Kathryn A Roupe,Chie Fukuda,etal.J Pharm Biomed Anal,2005,39:33
[14]Feng S S,Mei L,Panneerselvan Anitha,et al.Biomater,2009,30:3298
[15]CN:101721838
[16]樊明涛,吴守一,马海乐.江苏大学学报:自然科学版,2002,01:54
[17]宋志峰,王丽,纪锋,等.化学分析计量,2006,15(1):63
[18]邵裕坤,徐军,王珏.中国现代应用药学杂志,2005,22(6):503
[19]蔡乾蓉,吴卫,郑有良,等.食品科学,2010,31(6):243
[20]李彦,杨在宾,杨海勇,等.中国粮油学报,2009,24(1):141
[21]曹红翠.光谱实验室.2009,26(2):351
[22]冯新昌.中国卫生检验杂志.2001,11(1):57