可燃气体报警器属于国家强制检定项目,对可燃气体检测报警器进行不确定度评定对计量标准的传递起到了重要作用。依据JJF1059—2012《测量不确定度评定和表示》和JJG 693—2011《可燃气体检测报警器》计量检定规程,以可燃气体报警器示值误差为研究对象建立数学模型,分析仪器示值测量结果重复性标准不确定度、标准气体标称值准确度及稳定性的标准不确定度、被测仪器分辨力的不确定度对合成不确定度的影响,计算各分量灵敏度系数,并结合实验分析数据,以其作为评定可燃气体报警器不确定度的重要参考,以保证测量结果的科学性。
Alarmer detectors of combustible gas belong to the national compulsory verification project. The evaluation of uncertainty of the combustible gas detector plays an important role in the transmission of the measurement standard. According to JJF1059—2012 " The Evaluation of Measurement Uncertainty and Expression" and JJG 693—2011 " Alarmer Detectors of Combustible Gas",a mathematical model is set up with the value error of alarmer detectors of combustible gas as the research object. This paper analyses the standard uncertainty of measurement repeatability,the standard uncertainty accuracy and stability of nominal value of standard gas,and the uncertainty of measured instrument resolution influence on synthetic uncertainty,calculating sensitivity coefficient of the components combining with experimental analysis data,as the important reference for evaluation of uncertainty of alarmer detectors of combustible gas,to ensure the scientifictiy of measuring result.
引文
[1]王大伟.可燃气体检测报警器检定[J].大众标准化,2018(4):27-30.
[2]李远斌.可燃气体检测报警器计量检定与计量管理的探讨[J].中国标准化,2018(6):178-180.
[3]刘志娟,许峰,张文申,等.JJG 693—2011《可燃气体检测报警器》检定结果不确定度的评定[J].低温与特气,2014,32(4):38-40,43.
[4]孙涛.可燃气体检测报警器测量值的不确定度的评定[J].计量与测试技术,2014,41(7):97,99.
[5]王振,马广利,孙振,等.浅谈可燃气体报警器检定装置计量标准的建立[J].安全、健康和环境,2013,13(12):18-21.
[6]倪育才.实用测量不确定度评定[M].北京:中国检验出版社,2014.