智能变电站低压交流电源监控、测量装置采用了新的接线方式,以PC级ATS开关为主进线,主母线为双路电源进线,单母线不分段。,对进线电源监控、母线电量监测、电能计算和馈线监控而言,智能变电站低压交流电源监控、测量装置设置了六种工作模式供用户自由选择,具有通信功能,可实现四遥,方便接入综合自动化系统,能满足智能变电站的需求。
The monitoring and measuring device of low-voltage AC power supply in intelligent substation adopts a new wiring mode,with PC ATS switch as the main line,main bus as the dual power supply line,and single bus as the nonsegmented one. In terms of power supply monitoring,bus power monitoring,power calculation and feeder monitoring,the intelligent substation low-voltage AC power supply monitoring and measuring device has six working modes for users to choose freely. It has communication function,realizes four remote,facilitates access to integrated automation system,and meets the needs of intelligent substation.
引文
[1]杨道锦.500k V智能变电站设计思路和建设模式[J].通讯世界,2018,(1):185-187.
[2]李增高,李淑会,刘文生,等.变电站低压备自投的原理[J].科技创新与应用,2014,(26):178.
[3]张海平,柴宜,王琳琳,等.变电站交直流一体化电源系统全模块化应用研究[J].科技创新与应用,2018,252(32):186-187,190.
[4]赵贤龙.智能变电站低压侧分段保护装置二次回路改进[J].农村电工,2018,(11):45.