装配式栓钉剪力连接件抗剪承载力试验研究
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Experimental Study on Shear Capacity of Prefabricated Composite Shear Stud
  • 作者:杨未蓬 ; 李成君 ; 宋小明 ; 周志祥
  • 英文作者:YANG Weipeng;LI Chengjun;SONG Xiaoming;ZHOU Zhixiang;School of Civil Engineering,Chongqing Jiaotong University;Sichuan Vocational and Technical College of Communications;Chengdu Metro Management Co.Ltd.;State Key Laboratory Cultivation Base of Mountain Bridge and Tunnel Engineering,Chongqing Jiaotong University;
  • 关键词:钢混组合结构 ; 装配式施工方法 ; 抗剪试验 ; 抗剪承载能力 ; 栓钉
  • 英文关键词:Steel-concrete composite structure;;Prefabricated construction method;;Shear test;;Shear bearing capacity;;Stud
  • 中文刊名:TDJZ
  • 英文刊名:Railway Engineering
  • 机构:重庆交通大学土木工程学院;四川交通职业技术学院;成都地铁运营有限公司;重庆交通大学山区桥梁与隧道工程国家重点实验室培育基地;
  • 出版日期:2019-06-20
  • 出版单位:铁道建筑
  • 年:2019
  • 期:v.59;No.544
  • 基金:国家自然科学基金(51778094);; 重庆交通大学研究生教育创新基金(2017B0102);; 云南省交通运输厅科技项目(云交科(2018)28号)
  • 语种:中文;
  • 页:TDJZ201906010
  • 页数:5
  • CN:06
  • ISSN:11-2027/U
  • 分类号:43-47
摘要
为探索装配式栓钉在荷载作用下的力学性能,设计了2个大比例尺的预制装配式栓钉剪力连接件,通过推出试验研究其破坏过程、荷载滑移曲线、抗剪性能和极限承载力。研究结果表明:当栓钉被剪断时,栓钉根部剪断位置处有颈缩现象且局部混凝土剥落,栓钉周边混凝土仅出现细小裂纹,没有明显贯穿式裂纹;由于桥道板板肋处混凝土受传力钢板的约束作用使得板肋处混凝土和钢结构间摩擦力增大,进而提高了装配式栓钉剪力连接件的抗剪承载能力;在考虑滑移沿试件高度不均匀分布系数对结构影响的基础上,推导了在考虑混凝土弹性模量、栓钉弹性模量、栓钉直径、栓钉数量等因素的装配式栓钉剪力连接件单钉极限承载力理论计算公式,且计算结果的安全富余度满足规范要求,与试验结果相比,误差在5%以内,吻合较好。
        In order to explore the mechanical properties of the prefabricated studs under load action,two large-scale prefabricated composite shear stud( PCSS) were designed. The failure process,load-slip curve,shear resistance and ultimate bearing capacity of studs were obtained by push-out test.The judgment mark at the end of this test is the shear failure of studs. The research results show that when the stud is cut off,there is necking phenomenon at the cutting position of the stud root and local concrete peeling off.There are only small cracks in the concrete around the stud,and no obvious penetration cracks.Because of the restraint effect of the steel plate on the concrete at the rib of the bridge slab,the friction between the rib concrete and the steel structure increases,and the shear bearing capacity of the prefabricated composite shear stud is improved.Based on the inf luence of the uneven distribution coeff icient of the slip along the height of the specimen on the structure,the theoretical formulas for calculating the ultimate bearing capacity of single stud of prefabricated composite shear stud are derived considering the factors of concrete elastic modulus,stud elastic modulus,stud diameter and number of studs.The safety redundancy of the calculated results meets the requirements of the code.Compared with the test results,the error is less than 5%,which is in good agreement.
引文
[1]周志祥.PCSS剪力联结构造:0130786.4[P].2016-09-31.
    [2]周志祥.预应力钢桁混凝土组合连续刚构桥梁及施工方法:ZL200910104675.X[P].2012-07-04.
    [3]SLUTTER R G,DRISCOLL G C.Flexural Strength of SteelConcrete Composite Beams[J].Journal of the Structural Division,1965,91(2):71-99.
    [4]聂建国,沈聚敏,袁彦声.钢混凝土组合梁中剪力连接件实际承载力的研究[J].建筑结构学报,1996,17(2):21-29.
    [5]AN L,CEDERWALL K.Push-out Tests on Studs in High Strength and Normal Strength Concrete[J].Journal of Constructional Steel Research,1996,36(1):15-29.
    [6]丁发兴,倪明,龚永志,等.栓钉剪力连接件滑移性能试验研究及受剪承载力计算[J].建筑结构学报,2014,35(9):98-106.
    [7]薛伟辰,丁敏,王骅,等.单调荷载下栓钉连接件受剪性能试验研究[J].建筑结构学报,2009,30(1):95-100.
    [8]DANIEL L,RAJ D,CHARLES C.Characterization of the Splitting Behavior of Steel-Concrete Composite Beams with Shear Stud Connection[J].Procedia Material Science,2014,3:2174-2179.
    [9]宋小明.装配式钢混凝土组合构件的剪力联结受力性能试验研究[D].重庆:重庆交通大学,2017.
    [10]李成君,周志祥,黄雅意,等.装配式组合梁剪力钉抗剪承载力研究[J].中国公路学报,2017,30(3):264-270.
    [11]中华人民共和国住房和城乡建设部,中华人民共和国国家质量监督检验检疫总局.钢混凝土组合桥梁设计规范:GB 50917-2013[S].北京:中国计划出版社,2014.
    [12]张庭杰.PCSS剪力连接件极限承载力计算方法研究[D].重庆:重庆交通大学,2016.
    [13]蔺钊飞,刘玉擎,贺君.焊钉连接件抗剪刚度计算方法研究[J].工程力学,2014,31(7):85-90.