摘要
轨道电路分路不良是铁路行车安全的重大隐患,将导致轨道占用检测失效,引发铁路行车安全事故。在分析轨道电路分路不良原因的基础上提出一种新的摄像头以及红外对射、超声波测距组合的新方案,从而提高列车运行的可靠性和安全性。
Bad Shunting of track circuit is a significant risk of railway traffic safety.Which will lead to poor conductivity,track occupancy detection failure and railway traffic safety accidents.Based on the analysis of the causes of bad shunting of track circuit,a new scheme of the combination of new camera,infrared sensors and ultrasonic ranging is put forward in order to improve the reliability and safety of train operation.
引文
[1]吴江娇,王亚菊.客运专线列控中心对轨道电路分路不良的防护[J].北京交通大学学报,2008,32(3):21-24.
[2]李铭,赵晔.三点检查逻辑对区间轨道电路分路不良的防护研究[J].铁路通信信号工程技术,2012,9(3):59-61.
[3]胡永生.轨道电路分路不良整治方案研究[J].铁道通信信号,2008,44(5):24-26.
[4]徐炳辉,利用主动红外监测装置解决分路不良问题[J].铁道通信信号,2007,43(5):9-10.
[5]符萌,郭进,王小敏.铁路信号设备可靠性研究[J].中国铁路,2009(12):56-59.