应用精密过滤输液器输注抗肿瘤辅助用药的临床观察
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Intravenous injection of anti-cancer adjuvant drugs by precise filtering infusion apparatus
  • 作者:魏少美 ; 董寒玉 ; 马其冬
  • 英文作者:WEI Shao-mei;DONG Han-yu;MA Qi-dong;Department of Medical Oncology,The First Affiliated Hospital of Bengbu Medical College;
  • 关键词:输液疗法 ; 精密过滤输液器 ; 抗肿瘤辅助用药 ; 输液反应 ; 静脉炎
  • 英文关键词:infusion therapy;;precise filtering infusion;;cancer chemotherapy drug-assisted;;infusion reaction;;phlebitis
  • 中文刊名:BANG
  • 英文刊名:Journal of Bengbu Medical College
  • 机构:蚌埠医学院第一附属医院肿瘤内科;
  • 出版日期:2014-09-15
  • 出版单位:蚌埠医学院学报
  • 年:2014
  • 期:v.39;No.225
  • 语种:中文;
  • 页:BANG201409059
  • 页数:3
  • CN:09
  • ISSN:34-1067/R
  • 分类号:153-155
摘要
目的:探讨应用精密过滤输液器减少抗肿瘤辅助用药所致的输液反应和静脉炎的效果。方法:将306例静脉输注抗肿瘤辅助用药的恶性肿瘤患者随机分为观察组150例和对照组156例。观察组使用一次性精密过滤输液器输液,对照组使用一次性普通输液器输液。比较2组患者输液过程中输液反应和静脉炎的发生情况。结果:观察组与对照组输液反应的总发生率分别为6.7%和21.1%,静脉炎的总发生率分别为7.3%和26.9%。观察组输液反应和静脉炎的发生率均显著低于对照组(P<0.05~P<0.01);观察组静脉炎的程度较对照组明显减轻(P<0.01)。结论:使用精密过滤输液器能有效减少抗肿瘤辅助用药所致输液反应和静脉炎的发生。
        Objective: To investigate the effect of precise filtering infusion in reducing the infusion reaction and phlebitis induced by anti-cancer adjuvant drugs. Methods: A total of 306 cancer patients receiving intravenous infusion of anti-cancer adjuvant drugs were randomly divided into observation group( 150 cases) and control group( 156 cases). The patients in the observation group used disposable precise filtering infusion apparatus and the patients in the control group ordinary syringe injection. The incidence of infusion reaction and phlebitis in the two groups was observed and compared. Results: The total incidence of infusion reaction was 6. 7% and21. 1% in the observation group and the control group,respectively; the total incidence of phlebitis was 7. 3% and 26. 9% in the observation group and the control group,respectively. The incidence of infusion reaction and phlebitis in the observation group was significantly lower than that in the control group( P < 0. 05 to P < 0. 01); the phlebitis in the observation group was relieved significantly( P <0.01). Conclusions: Application of precise filtering infusion apparatus can effectively reduce the occurrence of infusion reaction and phlebitis induced by intravenous injection of anti-cancer adjuvant drugs.
引文
[1]徐伟,范朝志.药物不良反应报告216例分析[J].蚌埠医学院学报,2012,37(8):972-974.
    [2]劳丽霞,刘翠霞,赵进,等.精密过滤输液器在心血管疾病中的应用[J].护理实践与研究,2010,7(7):90-91.
    [3]陶源,孙国珍,龚婷,等.精密过滤输液器预防盐酸胺碘酮注射液所致静脉炎的临床观察[J].江苏医药,2011,37(17):2093-2094.
    [4]景冬梅,高勇.精密过滤输液器减少老年病人静脉炎的临床效果分析[J].全科护理,2012,10(2):398-399.
    [5]闫玉梅.儿童精密过滤输液器减少输液反应的疗效观察[J].护理研究,2010,24(7):1945.
    [6]毕儿珊.精密过滤输液器在急诊中的应用[J].全科护理,2010,8(6):1636-1637.
    [7]陆凤芹,吴瑞芹,张宏.精密过滤输液器减少输液反应的效果观察[J].齐鲁护理杂志,2007,13(7):144-145.
    [8]朱相格,张红,沈倩,等.精密过滤输液器在中药注射液静脉输注中的效果观察[J].实用医药杂志,2008,25(11):1361.
    [9]程乐梅,徐靖,马常转,等.精密过滤输液器输注抗肿瘤中药的临床观察[J].现代护理,2006,12(22):2131-2132.