细节保持的锥束CT环形伪影校正(英文)
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Detail-preserving ring artifact correction method for cone-beam CT
  • 作者:侯慧玲
  • 英文作者:HOU Hui-ling;Key Laboratory of Instrumentation Science & Dynamic Measurement (North University of China),Ministry of Education;School of Information and Communication Engineering,North University of China;
  • 关键词:锥束CT ; FDK算法 ; 环形伪影 ; 细节保持
  • 英文关键词:cone beam computed tomography(CT);;Feldkamp-Davis-Kress(FDK)algorithm;;ring artifacts;;detail-preserving
  • 中文刊名:CSKX
  • 英文刊名:测试科学与仪器(英文版)
  • 机构:中北大学仪器科学与动态测试教育部重点实验室;中北大学信息与通信工程学院;
  • 出版日期:2016-06-15
  • 出版单位:Journal of Measurement Science and Instrumentation
  • 年:2016
  • 期:v.7;No.26
  • 基金:National Natural Science Foundation of China(No.6171177);; National Key Scientific Instrument and Equipment Development Project(No.2013YQ240803)
  • 语种:英文;
  • 页:CSKX201602012
  • 页数:6
  • CN:02
  • ISSN:14-1357/TH
  • 分类号:67-72
摘要
环形伪影的存在严重影响CT图像重建质量,特别是在大型工件的CT检测中尤为严重。本文对一种重建后处理的伪影校正方法进行改进,以快速有效地消除CT图像环形伪影。首先,将CT图像从直角坐标系转到极坐标系,在极坐标系下设计多维滤波器对图像进行滤波处理。计算滤波后每个像素的均值和方差,通过计算的方差与方差阈值的比较以及像素值与像素值阈值的比较,双重精确确定伪影点的位置,对伪影点进行合理修正。之后,进行细节保持。最后,将校正后的极坐标图像转回直角坐标系。实际CT实验表明,与原方法相比,本文改进方法能更好地校正环形伪影,并保持图像细节信息,是一种实用的环形伪影校正方法,为后续处理和定量分析奠定基础。
        Ring artifact is the major factor that seriously influence quality of computed tomography(CT)image reconstruction,especially in testing large-scale workpieces.To remove ring artifact quickly and efficiently,a kind of ring artifact correction method is improved based on the post-processing CT image reconstruction in this paper.At first,transform the CT image from the rectangular coordinates into polar coordinates.Next,design multidimensional filter to filter the image and calculate the mean and variance of each filtered pixel in polar coordinates.The location of artifact point is determined by the double precision.One is the comparison of calculated variance and variance threshold,and another is the comparison of pixel value and pixel value threshold.Then,process the artifact points in a reasonable manner and do details remain to CT image in particular.At last,convert corrected polar image into rectangular coordinates.The actual experiment shows that compared with the original method,improved method can better correct the ring artifacts and keep the image details for CT images.It is a kind of practical ring artifact correction methods for subsequent processing and quantitative analysis.
引文
[1]Laskov V V,Simonov E N.Reduction of ring artifacts in computer tomography.Biomedical Engineering,2016,49(5):274-277.
    [2]Jha D,Srensen H O,Dobberschütz S,et al.Adaptive center determination for effective suppression of ring artifacts in tomography images.Applied Physics Letters,2014,105(14):143107.
    [3]YAN Lu-xin,WU Tao,ZHONG Sheng,et al.A variation-based ring artifact correction method with sparse constraint for flat-detector CT.Physics in Medicine and Biology,2016,61(3):1278-1292.
    [4]XIA Xiong-jun.Reduction of radiation image noise and CT ring artifacts.Master thesis.Beijing:Tsinghua University,2007.
    [5]LI Jun-jiang,HU Shao-xing,LI Bao-lei,et al.Ring artifact correction for industrial CT images.Journal of Beijing University of Aeronautics and Astronautics,2007,33(11):1398-1382.
    [6]MA Ji-ming,SONG Yan,WANG Qun-shu,et al.Ring artifact correction for X-ray computed tomography.High Power Laser and Particle Beams,2014,26(12):1-6.
    [7]SUN Hai-ning,QIU Shao-kun,LOU Shan-shan,et al.A correction method for nonlinear artifacts in CT imaging.In:Proceedings of the 26th Annual International Conference of the IEEE EMBS,San Francisco,2008:1290-1293.
    [8]Raven C.Numerical removal of ring artifacts in micro tomography.Review of Scientific Instruments,1998,69(8):2978-2980.
    [9]Münch B,Trtik P,Marone F,et al.Stripe and ring artifact removal with combined wavelet-Fourier filtering.Optics Express,2009,17(10):8567-8591.
    [10]GUO Hong,ZENG Dong,ZHANG Hua,et al.CT ring artifact reduction using an improved wavelet filtering in the sinogram domain.Journal of Southern Medical University,2015,35(9):1258-1262.
    [11]Raupach R.Method for removing rings and partial rings in computed tomography images.United States Patent Application,20030103595,USA,2003.
    [12]Axelsson M,Svensson S,Borgefors G.Reduction of ring artifacts in high resolution X-ray microtomography images.In:28th Symposium of the German Association for Pattern Recognition,Berlin,2006:61-70.
    [13]LI Bao-lei,YANG Min,FU Jian,et al.Two ring artifact correction methods for computed tomography.Acta Optica Sinica,2009,29(7):1849-1853.
    [14]YANG Jun,ZHEN Xin,ZHOU Ling-hong,et al.Geometric correction for cone-beam CT reconstruction and artifacts reduction.In:2nd International Conference on Bioinformatics and Biomedical Engineering,Shanghai,2008:2386-2389.
    [15]Feldkamp L A,Davis L C,Kress J W.Practical cone beam algorithm.J.Opt.Soc.AM.A,1984,1(6):612-619.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700