冬季低温条件下城区河道水质净化处理现场工程试验研究
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:The Pilot-plant Research on the Water Quality Improvement of Typical Urban River in the Condition of Low Temperature
  • 作者:吴华财 ; 赵微人 ; 李拓
  • 英文作者:WU Huacai;ZHAO Weiren;LI Tuo;China Water Resources Pearl River Planning Surveying&Designing Co., Ltd;Center for Water Ecological Engineering, Pearl River Water Resources Commission of the Ministry of Water Resources;Guangzhou Municipal Engineering Design&Research Institute;
  • 关键词:河道水质 ; 净化处理 ; 冬季低温 ; 现场工程试验
  • 英文关键词:river water quality;;purification treatment;;winter low temperature;;field engineering test
  • 中文刊名:RMZJ
  • 英文刊名:Pearl River
  • 机构:中水珠江规划勘测设计有限公司;水利部珠江水利委员会水生态工程中心;广州市市政工程设计研究总院;
  • 出版日期:2019-04-16 14:55
  • 出版单位:人民珠江
  • 年:2019
  • 期:v.40;No.252
  • 基金:水利部水利先进实用技术示范项目(SF-PX-201821)
  • 语种:中文;
  • 页:RMZJ201904002
  • 页数:5
  • CN:04
  • ISSN:44-1037/TV
  • 分类号:12-15+48
摘要
针对冬季低温条件下城区河道水质难以保持的特点,研究采用强化混凝沉淀+活性炭过滤两段式组合处理工艺对河道水质净化处理的效果。现场工程试验结合取水泵站设施和局部河段来完成水质净化工艺处理过程,考察冬季河道低温水工况下的净化处理效果。现场工程试验结果表明,在冬季河道水体水温约5. 5℃~8. 5℃时,絮凝剂(PAC)投加量4 mg/L、助凝剂(PAM)投加量0. 03 mg/L对水质的净化处理效果最佳。此时河道水体浊度去除率96%、透明度1. 2 m、CODMn去除率34. 9%、TP去除率约90. 2%,滤后水中残余铝和丙烯酰胺单体均满足国标限值要求,其中残余铝浓度有所增加但低于国标标准限值,丙烯酰胺单体低于检测值。采用Delta-tox生物毒性测试系统结果表明,当PAC投加量超过5 mg/L时,滤后水对水体中微生物生命活动表现出一定的抑制作用。比较分析处理前后底泥颗粒粒径分布情况,净化处理后底泥颗粒粒径有所增大,有助于悬浮物和胶体物质的吸附和沉降。
        In view of the difficulty in maintaining water quality in urban rivers under low temperature conditions in winter, the effect of enhanced coagulation sedimentation + activated carbon filtration two-stage combined treatment on river water purification treatment was studied. The on-site engineering test combines the water pumping station facilities and local river sections to complete the water purification process, and investigates the purification treatment effect of the winter river channel under low temperature water conditions. The result shows the optimum doses of PAC and PAM are 4 mg/L and 0. 03 mg/L respectively when the water temperature is between 5. 5℃ to 8. 5℃ and the remove rate of turbidity, CODMn, TP is 96%,34. 9% and 90. 2% respectively. The residual aluminum concentration is far below the national limit and the amount of acrylamide monomer in the effluent is below the detection limit. The result of Delta-tox biological toxicity system shows the effluent after activated carbon filtration causes the inhibition of micrograms when the dose of PAC is over 5 mg/L. According to analysis of the particle size distribution, the particle size of sediment is become larger,which can improve the ability of flocculation and settlement.
引文
[1]霍明昕,刘馨远.低温低浊水质特性的分析[J].中国给水排水,1998,14(6):33-34.
    [2]汤鸿霄.水体颗粒物和难降解有机物的特性与控制技术原理[M].北京:中国环境科学出版社,2000.
    [3]宋武昌,陈家全,石容,等.常规工艺水厂低温低浊期的强化混凝生产性实验研究[J].水处理技术,2015,41(6):71-74.
    [4]李桂平,栾兆坤.微絮凝-直接过滤工艺在城市污水深度处理中的应用研究[J].环境污染治理技术与设备,2002,3(4):65-68.
    [5]国家环保总局《水和废水监测分析方法》编委会.水和废水监测分析方法[M].4版.北京:中国环境科学出版社,2009.
    [6]生活饮用水卫生规范:GB 5749-2006[S].2001.
    [7]河流泥沙颗粒分析规程:SL 42-2010[S].2010.
    [8]汤鸿霄.无机高分子絮凝理论与絮凝剂[M].北京:中国建筑工业出版社,2006.
    [9]JEKEL M R.Removal of Al in coagulation and acidic raw water[J].Water supply,1991,26(3):9-12.
    [10]刘文新,栾兆坤,汤鸿霄.饮用水中铝的生物可给性研究[J].环境与健康,1997,14(1):44-46.
    [11]XU H,JIAO R Y,XIAO F,et al.Relative importance of hydrolyzed Al species(Ala,Alb,Alc)on residual Al and effects of nano-particles(Fe-surface modified Ti O2and Al2O3)on coagulation process[J].Physicochemical and Engineering Aspects,2014,446:139-150.
    [12]吴华财.城市感潮河道污染底泥原位处理小试研究[J].人民珠江,2012(5):54-58.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号