摘要
第一自来水厂响应水务集团挖潜降耗的号召,积极开展供水节能技术改造工作。在对取、送水机泵运行工况进行科学评估的基础上,经过专业分析与讨论,完成了切合生产实际的改造工作。该工作不仅大大提高了水厂的日供水量并储备了更高的供水能力,满足了城市发展的需要,还取得明显的节能效果。
In response to the Water Group's suggestion—increasing the production potential of the machine and reducing energy consumption, team of the First Waterworks has actively worked on technology reformation of energy saving in water supply. The running condition of the water intake pump and distribution pump had been evaluated. Through professional technical analysis and team discussion,the transformation of pumps had been completed according to the practical production. The daily water supply capacity and water reservation capacity have been greatly increased,which is adapted to the needs of urban development,and obvious energy saving effect have been obtained.
引文
[1]何桂洪,杭滨,胡家乐,等.新基加压站节能改造典型案例分析[J].广东供水,2016,30(2):21-28.
[2]岳建祥.水泵叶轮切削的能效分析[J].产业与科技论坛,2011,10(15):69-70.
[3]张焕俐.水泵叶轮切削在水厂节能技术改造中的应用[J].城镇供水,2010(6):28-30.