摘要
为实现稠油热采过程中单井注蒸汽流量和干度的准确计量,从而提高注蒸汽的热效率,该文通过对两相流孔板差压噪声的深入研究,建立了能够同时测量注入蒸汽流量和干度的理论模型。在此基础上,采用Morris参数敏感性分析方法对模型的关键参数进行了敏感性分析,确定各相关参数对模型输出表现的差异。现场应用时通过设定合理的修正参数,实现流量相对误差小于0.1%、热量相对误差小于0.2%。
For the measurement of steam in the heavy oil heating-recovery process,which can improve the thermal efficiency of steam injection. The study on the differential pressure noise of orifice in two-phase flow has been achieved,and a theoreti cal model has been obtained for simultaneous measurement of mass flow rate and steam quality. On this basis,the sensitivity analysis has been performed adopting Morris approach for key parameters of the model,which ensure the reliability of the flow data of single well. By setting reasonable correction parameters in the field application,the relative error of flow rate is less than 0.1%,and the relative error of heat metering is less than 0.1%.
引文
[1]王文然,蒋跃元,门相卿,等.稠油热采注入饱和蒸汽的计量和调节[J].清华大学学报:自然科学版,2000,40(12):29-32.
[2]王文然,佟允宪,马昌文.利用孔板差压噪声测量两相流流量和干度的研究[J].清华大学学报,1993,33(S3):117-124.
[3]周明正,刘云焰,赵瑞昌,等.孔板蒸汽流量计非稳定状态测量分析[J].自动化仪表,2015,36(9):92-95.
[4]欧阳雪峰.孔板流量计用于蒸汽计量[J].仪表电气,2013,32(6):85-86.
[5]郑建英,陈超洋,马龙博,等.蒸汽状态给蒸汽计量带来的误差[J].自动化仪表,2009,30(7):31-32.
[6]毕英,许传军,许文达,等.蒸汽流量计量现状及存在问题[J].工业计量,2015(S1):5-7.
[7]成宏宇.差压式流量计在蒸汽计量中的应用.甘肃冶金,2008,30(2):76-78.
[8]仲朔平,佟允宪,王文然.利用孔板差压噪声测量汽水两相流[J].清华大学学报:自然科学版,1997,37(5):15-18.
[9]Campolongo F,Cariboni J,Saltelli A.An effective screening design for sensitivity analysis of large models[J].Environmental Modeling&Software,2007,22(10):1509-1518.