基于水力模型的供水管网DBS分区及检漏研究
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:DBS implementation of water distribution newtork by using a hydraulic model and its application in NRW reduction
  • 作者:薛峰 ; 郭瑾 ; 郑胜达 ; 赵洪宾 ; 赵明
  • 英文作者:Xue Feng;Guo Jin;Zheng Shengda;Zhao Hongbin;Zhao Ming;Shanghai Qingpu District Water Supply Management Unit;Shanghai Qingpu Water Supply Limited Company;Tianjin Sambo Water Technology Co., Ltd.;Harbin Institute of Technology;
  • 关键词:供水管网 ; 水力模型 ; DBS ; 漏损控制 ; 产销差
  • 英文关键词:Water distribution network;;Hydraulic model;;DBS;;Leakage control;;Non-revenue water ratio
  • 中文刊名:JZJS
  • 英文刊名:Water & Wastewater Engineering
  • 机构:上海市青浦区供水管理所;上海青浦自来水有限公司;天津三博水科技有限公司;哈尔滨工业大学;
  • 出版日期:2019-05-10
  • 出版单位:给水排水
  • 年:2019
  • 期:v.55;No.457
  • 语种:中文;
  • 页:JZJS201905015
  • 页数:4
  • CN:05
  • ISSN:11-4972/TU
  • 分类号:131-134
摘要
为了解决上海市青浦区赵巷地区供水系统的产销差居高不下问题,应用基于水力模型的区块化(Distribution Blocking System,DBS)分区技术,将其供水管网分成7个相对独立的区域。DBS与传统的管网分区或DMA不同,不仅可以降低漏水量,同时也可改善水质与水压。DBS区块化之后平均水龄相比区块化之前降低了12.9%,管网末端余氯提高了10.6%。整体管网压力较区块化之前更为均衡,与2016年相比,2017年的进水总量下降了140.72万m~3,售水量提升了33.28万m~3,产销差降低了7.73%。实践表明,在水力模型建立的基础上实施DBS分区计量是行之有效的漏控管理方式之一,不仅能够为供水企业带来经济效益,而且能均衡水压、改善水质。
        In order to reduce non-revenue water of water distribution systems in Zhaoxiang Area located within Qingpu District in Shanghai, Distribution Blocking System(DBS) is developed based on a hydraulic model and multi-leveling by function. The water distribution systems are divided into 7 relatively independent blocks(sub-systems) by using the developed DBS which is different with traditional zoning or District Meter Area(DMA). As a result, compared with 2016, the average water age in the distribution systems is reduced by 12.9% and residual chlorine at the ends of the distribution systems is increased 10.6% in 2017. Moreover, the pressure ranges in the distribution systems trend to be more equal. Consequently, no-revenue water ratio is reduced by 7.73%. The results show that the developed DBS method has very good efficacies in water leakage reduction, improvement of water quality and pressure distribution.
引文
[1] 单国平,丁宏进,张俊杰.独立计量分区在南京水司降低产销差中的应用[J].中国给水排水,2012,28(19):63-65.
    [2] 王圣.上海市小区给水管网漏损分析及分区计量管理研究[D].哈尔滨:哈尔滨工业大学,2017.