摘要
建立高效液相色谱法测定地表水中阿特拉津,用二氯甲烷萃取水体中的阿特拉津,浓缩定容后,以甲醇:水=7:3为流动相,用Eclipse XDB-C18进行分离,流速0.8m L/min,采用紫外检测器,外标法测定水体中阿特拉津含量,其相关系数为0.9998。该方法具有操作简便、分析速度快、定量分析结果准确、稳定等优点。
A high performance liquid chromatographic method was used for the determination of atrazine in surface water, atrazine was extracted from the water by dichloromethane. After concentreated,they were separated on Eclipse XDB-C18 with methanol:water=7:3 as mobile phase,the flow rate 0.8 m L/min.The detection of atrazine in water by external standard method was made on the ultraviolet detector,and the correlation coefficient is 0.9998.The method has the advantages of simple,rapid,accurate and stable.
引文
[1]刘爱菊,朱鲁生,王军等.除草剂阿特拉津的环境毒理研究进展[J].土壤与环境,2002,11(4):405-408.
[2]陶庆会,汤鸿霄.共存污染物对阿特拉津在天然沉积物上吸附的影响[J].环境科学报,2004(4):20-21.
[3]HJ 587-2010,水质阿特拉津的测定,高效液相色谱法[S].
[4]植深晓,潘锦.液液萃取—高效液相色谱法测定水体中的阿特拉津[J].东莞理工学院学报,2014,21(3):65-68.