摘要
采用超临界CO_2萃取技术(SFE-CO_2)从纺织品中萃取了邻苯二甲酸酯类增塑剂。探讨了不同萃取条件(萃取压力、萃取温度、萃取时间、共溶剂种类、收集溶剂种类)对邻苯二甲酸酯萃取率的影响,建立了超临界CO_2流体萃取/气相色谱-质谱联用(SFE-CO_2/GC-M S)法测定纺织品中13种邻苯二甲酸酯的检测方法。研究表明:采用正己烷为共溶剂和接收剂,萃取温度60℃、压力35 M Pa,萃取时间60 min的条件最佳,萃取物经GC-M S测定,邻苯二甲酸二异癸酯在10~1000μg/m L范围内线性关系良好,其余12种邻苯二甲酸酯在1~500μg/m L范围内线性关系良好,相关系数为0.9917~0.9994,加标回收率在80.0%~117.2%之间,RSD在1.1%~7.2%之间。
The phthalate in textiles was extracted by means of supercritical CO_2 extraction technology( SFE-CO_2). The effects of different extraction conditions( the pressure,temperature and time of extraction,the variety of co-solvent and trapping solvent) on the extraction yield of the phthalate were discussed. A method was established for the determination of thirteen phthalate in textiles by using supercritical CO_2 fluid extraction and gas chromatography( SFE CO_2/GC-MS). The results showed the optimum extraction conditions wereas following: both co-solvent and trapping solvent were n-hexane,respectively,the temperature was 60℃,the pressure was 35 MPa,the dynamic extraction time was60 min. The calibration curveof Di-iso-decylphthalate( DIDP) was linear in the range of 10 ~1000 μg/m L,and 1 ~ 500 μg/m L for the others 12 kinds of PAEs,with correlation coefficients of0. 9917 ~ 0. 9994. The average recoveries of target compounds in sample were in the range of80. 0% ~ 117. 2%,and the relative standard deviations were between 1. 1% and 7. 2%.
引文
[1]Niu Z Y,Ye X W,Fang L P,Xue Q H,Sun Z S.Chinese J.Chromatogr.,2006,24(5):503牛增元,叶曦雯,房丽萍,薛秋红,孙忠松.色谱,2006,24(5):503
[2]OEKO-TEXS standard 100:General and special conditions.Oeko-Tex Association,2017
[3]Chen S D,Fei G Q.China Standardization,2017,(9):22陈山丹,费桂琴.中国标准化,2017,(9):22
[4]Lu Y,Yu W T,Mai B H,Zhang B,Liang S W,Yu W J.Chin.J.Anal.Lab.,2016,35(2):193卢瑜,禹伟腾,麦宝华,张斌,梁淑雯,于文杰.分析试验室,2016,35(2):193
[5]Ji H,Pu A J,Shen R J,Li X.Dyestuffs and Coloration,2014,(4):56季浩,蒲爱军,沈日炯,李信.染料与染色,2014,(4):56
[6]Wang C Y,Liu C M,Shi Q Y,Liu F P,Xie T T,Li X T,Li L X.J.Instrum.Anal.,2012,31(12):1550王成云,刘彩明,施钦元,刘福平,谢堂堂,李心恬,李丽霞.分析测试学报,2012,31(12):1550
[7]Li T B,Liu W,Wang C L,Yi B H.Chem.Anal.Meterage,2015,(4):99李天宝,刘炜,王春利,易碧华.化学分析计量,2015,(4):99
[8]Yan J,Bao F W,Niu L N,Su G S.J.Instrum.Anal.,2015,34(2):134阎瑾,鲍峰伟,牛丽娜,刘辉,苏国岁.分析测试学报,2015,34(2):134
[9]Xu D M,Zheng X H,Yang L Z,Fang E H,Chen L P,Lin L Y,Zhou Y.Chinese J.Anal.Chem.,2012,40(2):304徐敦明,郑向华,杨黎忠,方恩华,陈鹭平,林立毅,周昱.分析化学,2012,40(2):304
[10]Wu X Q,Ding Y C,Cao X Z,Tang J,Zhou J.Textile Auxiliaries,2014,31(11):48吴晓琼,丁友超,曹锡忠,汤娟,周佳.印染助剂,2014,31(11):48
[11]Zhou H B,Fang K Y.Plast.Sci.Technol.,2013,(4):98周宏斌,方科益.塑料科技,2013,(4):98
[12]He P.Chin.Plast.Ind.,2010,38(9):60何芃.塑料工业,2010,38(9):60
[13]Xue J.Food Eng.,2017,(1):25薛晋.食品工程,2017,(1):25
[14]Pang H Y,Huang L S,Wu H T,Chen Y P,Lin Y Y,Zhang Y N,Wang Y Y,Wang G H.Chin.J.Pharm.Anal.,2017,(9):1675庞海月,黄立森,吴黉坦,陈煜沛,林逸仪,张亚楠,王雅英,王贵弘.药物分析杂志,2017,(9):1675
[15]Huang L S,Zhang T X,Pang H Y,Wu H T,Ye Z J,Wang G H.Chem.y&Bioeng.,2016(7):58黄立森,张瞳昕,庞海月,吴黉坦,叶子坚,王贵弘.化学与生物工程,2016(7):58
[16]Xu J Q,Chen Y,Tan M L,Xu Q Q,Wu J.J.Instrum.Anal.,2017,36(6):762徐金巧,陈勇,谈满良,徐清泉,吴键.分析测试学报,2017,36(6):762