摘要
利用恒温恒湿环境仓模拟室外环境条件,对空气–水双热源复合热泵系统的单水源制热、单空气源制热和空气–水双热源制热3种运行模式在不同环境温度和湿度、低温水箱水温、水流量等参数条件下的系统性能系数COP进行分析研究,试验结果表明:单水源制热模式系统随低温水箱水温的升高呈上升趋势;单空气源制热时空气温度变化对系统COP影响较大;蒸发器进风温度和进水温度的有效温差是空气–水双热源制热时影响从空气侧和水侧同时获取热量的关键因素。
This paper used environmental chamber to simulate outdoor environmental conditions and analyzed system performance coefficient COP of air-water dual source compound heat pump system under three different operation modes, including single water source heating, single air source heating and air-water dual source heating, at different ambient temperature and humidity, water temperature and water flow of low temperature water tank. The test result showed that single water source heating mode COP became larger when the water temperature of low temperature water tank increased; air temperature variation of single air source heating had big influence on system COP; valid temperature difference between air intake temperature of evaporator and water inlet temperature is a key factor influencing simultaneous heat supply at air side and water side under air-water dual source heating mode.
引文
[1]KUANG Y H,WANG R Z,YU L Q.Experimental study on solar assisted heat pump system for heat supply[J].Energy Conversion&Management,2003,44(7):1089-1098.
[2]DIKICI A,AKBULUT A.Performance characteristics and energy exergy analysis of solar-assisted heat pump system[J].Building and Environment,2008,43(11):1961-1972.
[3]KADIR B,BEDRI Y.Experimental thermal performance of a solar source heat-pump system for residential heating in cold climate region[J].Applied Thermal Engineering,2011(31):1508-1518.
[4]KAYGUSUZ K,NURBAY G,TEOMAN A.Solar-assisted heat Pump and energy storage for domestic heating in Turkey[J].Energy Conversion and Management,1993,34(5):335-346.
[5]KAYGUSUZ K.Performance of solar-assisted heat-pump systems[J].Applied Energy,1995,51(2):93-109.
[6]KAYGUSUZ K.Experimental and theoretical investigation of a solar heating system with heat pump[J].Renewable Energy,2000,21(l):79-102.
[7]KAYGUSUZ K.Solar Heat Pumps[M].Amsterdam:Elsevier,2004.
[8]谌学先,高文峰,兰青,等.热泵与家用太阳热水器联合供热性能试验[J].农业工程学报,2011,27(2):272-275.
[9]KAYGUSUZ K,AYHAN T.Experimental and theoretical investigation of combined solar heat pump system for residential heating[J].Energy Conversion&Management,1999,40(13):1377-1396.
[10]KAYGUSUZ K.Experimental and theoretical investigation of a solar heating system with heat pump[J].Renewable Energy,2000,2(1):79-102.
[11]GUO J J,WU J Y,WANG R Z,et al.Experimental research and operation optimization of an air-source heat pump water heater[J].Applied Energy,2011,88(11):4128-4138.
[12]CHATURVEDI S K,ABDEL-SALAM T M,SREEDHARAN S S,et al.Two-stage direct expansion solar-assisted heat pump for high temperature applications[J].Applied Thermal Engineering,2009(29):2093-2099.
[13]LI H,YANG H X.Study on performance of solar assisted air source heat pump systems for hot water production in Hong Kong[J].Applied Energy,2010,87(9):2818-2825.
[14]PANARAS G,MATHIOULAKIS E,BELESSIOTIS V.Investigation of the performance of a combined solar thermal heat pump hot water system[J].Solar Energy,2013(3):169-182.
[15]王岗,全贞花,赵耀华,等.太阳能-空气复合热源热泵热水系统[J].化工学报,2014,65(3):1033-1039.
[16]LIU Y,ZHOU G H,MA J.Experimental investigation on a solar air heat pump by heat source[J].Energy Procedia,2012(14):1590-1594.
[17]陈晓宁,杨志宇,陈江平,等.北京地区户式空气源热泵地板辐射供热系统运行特性研究[J].建筑技术,2016,47(11):990-993.