摘要
针对辐射光谱测温法测量误差问题,利用黑体炉搭建了标准辐射测温实验平台,选用200~1 100nm波段光谱仪对标准高温源进行辐射光谱测量。讨论了高温源辐射光谱特征,并基于辐射光谱测温法获得了温度测量值,该值与标准参考值的相对偏差小于4%,同时分析了测量重复性引起的标准不确定度分量,为辐射测温法应用提供参考。
In order to obtain the measurement error of radiation spectroscopy thermometry,the standard experimental platform was established by black body furnace.The spectrometer with200~1 100 nm was selected to measure the radiation spectrums of standard high-temperature source.The spectral characteristics were discussed in detail.And the temperature results were determined based on spectroscopy thermometry.Compared with the standard value,the relative deviations are less than 4%. The uncertainty components of the repeated measurements were analyzed.It provides important reference for applications of radiation spectroscopy thermometry.
引文
[1]ECKBRETH A C.Laser Diagnostics for Combustion Temperature and Species[M].London:Taylor&Francis Books,Inc.,1996.
[2]戴景民,金钊.火焰温度测量技术研究[J].计量学报,2003,24(4):297-302.
[3]杨永军.温度测量技术现状和发展概述[J].计测技术,2009,29(4):62-65.
[4]刘利秋,卢艳军,徐涛.传感器原理与应用[M].北京:清华大学出版社,2015.
[5]HANSON P K.Applications of quantitative laser sensors to kinetics,propulsion and practical energy systems[J].Proceedings of the Combustion Institute,2011,33(1):1-40.
[6]MCKENZIE R L.Progress in laser spectroscopic techniques for aerodynamic measurements-An overview[J].AIAA Journal,1993,31(3):465-477.
[7]胡志云,刘晶儒,关小伟,等.燃烧场参数的激光诊断技术研究[J].强激光与粒子束,2002,14(5):702-706.
[8]蔡小舒,周骛,杨荟楠,等.燃烧与流场在线测量诊断方法研究进展[J].实验流体力学,2014,28(1):12-20.
[9]蔡小舒,罗武德.采用发射光谱法检测煤粉锅炉火焰的技术研究[J].动力工程,2000,20(6):955-959.
[10]程智海,蔡小舒.应用原子特征发射谱线法测量煤粉火焰温度[J].动力工程,2007,27(6):918-922.
[11]刘家汛,杨斌,蔡小舒.辐射光谱法电站锅炉燃烧检测诊断研究[J].工程热物理学报,2015,36(9):2055-2059.
[12]杨斌,桂欣扬,周骛,等.利用辐射光谱法开展发动机燃烧火焰参数在线测量[J].航空动力学报,2015,30(12):2904-2909.