摘要
为了解决浮选过程中人工加药的不准确性和不稳定性,研究提出采用蠕动泵为执行机构构建浮选自动加药系统,并进行试验探究其精度。经过大量的试验表明,在选择以200 mL为标准校准时,捕收剂的误差精度小于4%,起泡剂的误差精度小于1%。由此可见,蠕动泵是完全可以用于浮选自动加药系统的执行机构。
In view of the inaccuracy and instability of artificial agent dosing in flotation process, an automatic dosing system with peristaltic pump as actuating mechanism is developed, and its dosing accuracy is studied through test. Result of extensive tests shows that when standard calibration is made against 200 mL, the precision error of the system is less than 4% for dosing collector and smaller than 1% for dosing frother. As evidenced by test result, the peristaltic pump can successfully be used as the actuating mechanism of the automatic dosing system.
引文
[1] 李思, 李世厚.浮选自动加药机的研究概况[J].矿产保护与利用,2011(3):54-58.
[2] 李璐,董志勇,王然风.选煤厂浮选自动加药专家系统的设计与实现[J].煤炭工程,2013(11):16-18.
[3] 赵礼兵,李世厚.浮选自动加药控制的现状与发展[J].冶金自动化,2004,28(Z1):545-548.
[4] JS拉斯科夫斯基,郭秀平,李长根.煤的浮选及其未来[J].国外金属矿选矿,2007(2):18-23.
[5] 史纪录,朱正军.浮选自动加药装置的研制与应用[J].选煤技术,2014(3):68-71.
[6] 张志伟,范鸿卓.浮选加药自动控制系统的优化设计[J].选煤技术,2016(2):71-73.
[7] 王道臣,陈志军,韩玉明,等.蠕动泵流量的理论计算与试验验证[J].化工自动化及仪表, 2015(2):186-187.