本文介绍了北京某机关办公建筑暖通空调节能设计采用的关键技术,详细阐述了双冷源温湿度独立控制空调系统设备选型原则和设计参数取值依据,地板辐射供暖混水装置内部结构和运行调节机制,以及会议室竖壁贴附射流气流组织的CFD优化设计方法。
The key technologies used in the energy efficient design of HVAC in a government office building in Beijing are introduced. This paper elaborates the equipment selection principle and value basis of design parameters of the temperature and humidity independent processed air conditioning system based on double cold sources, and introduces the internal structure and operation mechanism of floor panel heating mixing device, also presents the optimization design method based on CFD of air curtain ventilation of the conference room.
引文
[1]田旭东,张秀平,杜立卫,等.温湿度独立控制系统用干式显热风机盘管的研究[J].暖通空调,2011,41(1):28-32.
[2]郑坤,潘云钢,韩武松,等.双温冷源温度湿度独立控制空调系统新风系统设计探讨[J].暖通空调,2014,44(8):31-34.
[3]中国建筑科学研究院.GB 50736-2012民用建筑供暖通风与空气调节设计规范[S].北京:中国建筑工业出版社,2012.
[4]李安桂,刘旺兴,要聪聪,等.竖壁贴附射流加导流板呼吸区送风气流组织CFD及试验研究[J].西安建筑科技大学学报(自然科学版),2016,48(5):738-744.
[5]冯慧.非等温水平贴附射流数值模拟[D].西安:西安建筑科技大学,2007.
[6]尹海国,李安桂.竖直壁面贴附式送风模式气流组织特性研究[J].西安建筑科技大学学报(自然科学版),2015,47(6):879-884.
[7]尹海国,李安桂,刘志永,等.基于方形柱面的贴附置换通风模式气流组织设计与应用[J].建筑技术开发,2016,43(10):7-10.