鄱阳湖区圩堤由于堤身环境、质量及区域地质条件等原因,易发生堤身渗漏和堤基管涌等险情,汛期高水位时,此类险情直接威胁圩堤安全。针对湖区西河东联圩堤身渗漏传统处置方法效果不佳的问题,采用高密度电阻率法探测隐患位置,为隐患处理提供了更为准确的依据,阐明了该方法用于防汛抢险的可行性和有效性,并对现场探测提出了建议。
Due to the causes of surrounding environment,dam quality and regional geological situation etc.,the polder embankments in Poyang Lake area are prone to suffering accidents of body seepage and foundation piping,which would directly threaten the embankment safety when the water level is high in flood season. To solve the poor-effective traditional leakage treatment method for Xihedong embankment,high-density resistivity survey was used to detect the hidden defects to provide more accurate evidence for treatment. The feasibility and effectiveness of the method are illustrated and the suggestions for in-situ probing are given.
引文
[1]黄浩智,李洪任.鄱阳湖区圩堤建设回顾与思考[J].江西水利科技,2014,40(1):67-69.
[2]肖翔,刘之葵,高伊航.高密度电法在黄土滑坡勘察中的应用[J].人民长江,2015,46(17):49-52.
[3]熊勇.高密度电法勘探中地形影响校正方法探讨[J].人民长江,2014,45(14):47-48.
[4]王兵,陆新,周培岳.高密度电阻率法在病坝水库探测中的应用[J].四川建筑,2007,27(6):111-113.
[5]廖从荣.高密度电阻率法在水库堤坝隐患探测中的应用效果分析[J].山西地震,2004(3):12-15.
[6]董延朋,万海.高密度电阻率法在堤坝洞穴探测中的应用[J].特探装备,2006,16(1):56-58.
[7]陆鹏飞.高密度电阻率法在堤防隐患探测中的应用[J].吉林水利,2007(12):32-34.
[8]刘思源.高密度电阻率法探测堤坝隐患初探[J].湖南水利水电,2000(4):23-26.
[9]葛双成,章晓华.堤坝隐患物理探测方法及其应用[J].浙江水利科技,2005(5):36-39.
[10]王小春,刘晓容,张绍付.江西省10万亩以上重点圩堤蚁害现状及防治对策[J].江西水利科技,2000,26(1):43-47.
[11]彭起胜.谈堤坝白蚁引发险情的抢护[J].江西水利科技,1999,25(4):222-224.
[12]章毅.圩堤堤基渗漏与整治[J].江西气象科技,1999(22):111-112.