薄膜体声波滤波器加速寿命评估技术研究
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Studying on Accelerated Life Assessment Technology of Film Bulk Acoustics Filter
  • 作者:张俊 ; 杜波 ; 徐园园 ; 刘洋宏 ; 曾小珊
  • 英文作者:ZHANG Jun;DU Bo;XU Yuan-yuan;LIU Yang-hong;ZENG Xiao-shan;No.26 Research Institute of CETC;
  • 关键词:敏感应力 ; 加速寿命 ; 寿命参数 ; 阿伦尼斯模型 ; 可靠性评估
  • 英文关键词:sensitive stress;;accelerated life;;life parameter;;Arrhenius model;;reliability assessment
  • 中文刊名:JSCX
  • 英文刊名:Equipment Environmental Engineering
  • 机构:中国电子科技集团公司第二十六研究所;
  • 出版日期:2019-07-25
  • 出版单位:装备环境工程
  • 年:2019
  • 期:v.16
  • 语种:中文;
  • 页:JSCX201907024
  • 页数:4
  • CN:07
  • ISSN:50-1170/X
  • 分类号:109-112
摘要
目的研究薄膜体声波滤波器的加速寿命评估技术,针对XXX1001型薄膜体声波滤波器进行可靠性寿命评估。方法根据薄膜体声波滤波器设计、结构特点,针对XXX1001型薄膜体声波滤波器典型应用环境条件下的失效模式和失效机理分析,采用环境影响分析明确寿命表征指标和相应敏感应力,以此确定合适的加速寿命方法和加速模型。结合可靠性摸底试验确定的敏感应力极限和加速模型要求,设计加速寿命试验方案,利用阿伦尼斯模型对寿命表征指标等试验数据进行评估,得到该型薄膜体声波滤波器的可靠性寿命参数。结果确定了滤波器的寿命表征指标(插入损耗)和敏感应力(温度),设计了加速寿命试验方案,试验实施后,根据试验数据评估出XXX1001型薄膜体声波滤波器在40℃工作时的平均寿命为117 803h。结论该技术程序较为简单、实施方便、样本少、成本低,可为类似滤波器的可靠性评估提供参考。其评估结果也可为XXX1001型薄膜体声波滤波器的设计改进和应用推广提供技术支撑。
        Objective To study the accelerated life assessment technology for the film bulk acoustic filter and evaluate the reliability life for the XXX1001 film bulk acoustic filter. Methods According to the design and structural characteristics of the film bulk acoustic filter, the failure mode and failure mechanism of the XXX1001 film bulk acoustics filter under the typical application environmental conditions were analyzed, and the analysis of environmental impact was adopted to make clear the life characterization index and the corresponding sensitive stress, to determine the appropriate accelerated life method and the accelerated model. In combination with the sensitivity stress limit and the requirement of accelerated model, the accelerated life test was designed and the reliability life parameter of this type of film bulk acoustics filter were obtained by evaluating the test data such as the life characterization index with the Arrhenius model. Results The life characterization index(insertion loss) and the sensitive stress(temperature) of the filter were obtained. The accelerated life test plan was designed. After testing, in combination with the test data, the average life of XXX1001 film bulk acoustic filter was evaluated to be 117 803 h when working in 40℃.Conclusion The technical procedure is simple, easy to implement, with few samples and low cost, which can provide a reference for the reliability evaluation of similar filters. The evaluation results can also provide technical support for the design improvement and application promotion for the XXX1001 film bulk acoustic filter.
引文
[1]李丽,郑升灵,李丰,等. S波段FBAR滤波器芯片的研制[J].压电与声光, 2013, 35(5):617-619.
    [2]胡瑛,梅盖华,周毅,等.声表面波滤波器寿命分布研究[J].压电与声光, 2013, 35(3):312-314.
    [3]刘良芳,张俊,刘晓琴,等.X454声表面波滤波器可靠性评估方法[J].四川兵工学报, 2014, 35(12):92-95.
    [4]赵艳涛,张文伟,姚军.基于退化量分布与退化轨迹的两种加速退化数据贮存寿命评估方法对比[J].环境技术, 2011(4):29-32.
    [5]王宇,王欣汝,黄进永,等.通用电子产品全寿命周期可靠性分析方法[J].电子产品可靠性与环境试验,2017, 35(1):40-44.
    [6]张睿,焦向全,马晋毅,等.薄膜体声波谐振器的热学分析[J].压电与声光, 2016, 38(1):1-4.
    [7]刘良芳,张俊,吴畏,等.光纤声光调制器可靠性强化试验方法研究[J].兵器装备工程学报,2018(10):134-137.
    [8]陈运详,董加和,司美菊,等.FBAR用氮化铝压电薄膜研究[J].压电与声光, 2015, 37(6):934-936.
    [9]宣亚龙,陈泽,刘亚超.红外敏感期加速寿命试验方法研究[J].装备环境工程, 2012, 9(6):44-46.
    [10]甘祖旺.加速寿命试验在产品变工况下退化数据归一化中的应用研究[J].自动化与信息工程,2015,36(6):23-28.
    [11]黄婷婷,姜同敏.加速寿命试验中统计加速模型综述[J].装备环境工程, 2010, 7(4):57-62.
    [12]梁经宛,刘志远,姜帅,等.长寿命电气二次设备的加速试验方法[J].电测与仪表, 2014, 51(10):39-44.