EDTA络合滴定法快速测定矿石中钙、镁
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Rapid Determination of Calcium and Magnesium in Ore by EDTA Complexometric Titration
  • 作者:韩晓
  • 英文作者:HAN Xiao;BGRIMM MTC Technology Technical Co.Ltd.;Beijing Key Lab of Mineral Resource Evaluation & Analysis;
  • 关键词:容量法 ; ICP-AES ; 矿石 ; ;
  • 英文关键词:volumetric method;;ICP-AES;;ore;;calcium;;magnesium
  • 中文刊名:WJFX
  • 英文刊名:Chinese Journal of Inorganic Analytical Chemistry
  • 机构:北矿检测技术有限公司;金属矿产资源评价与分析检测北京市重点实验室;
  • 出版日期:2019-04-15
  • 出版单位:中国无机分析化学
  • 年:2019
  • 期:v.9
  • 语种:中文;
  • 页:WJFX201902012
  • 页数:4
  • CN:02
  • ISSN:11-6005/O6
  • 分类号:58-61
摘要
试样用盐酸、硝酸、氢氟酸、高氯酸分解,在pH值为6~9时,经六次甲基四胺-铜试剂分离铁、铝、镍、钴、铅、锌、铜、镉、锰等干扰元素后,在pH=10的氨水和氯化铵缓冲溶液中,以酸性铬蓝K-萘酚绿B为指示剂,用EDTA络合滴定法测定钙镁合量;另在氢氧化钾溶液中,用钙试剂为指示剂,以EDTA络合滴定法测定钙量,从而计算镁的含量。当样品钙高镁低或者镁高钙低时,低含量的镁量或钙量(<5%)可用电感耦合等离子体原子发射光谱(ICP-AES)法准确测定,使结果更准确。实验中对三个标准样品中的钙和镁进行多次测定,结果与认定值相符,相对标准偏差在0.69%~1.3%(n=7),加标回收率在99%~102%。方法实用性强,已经成功应用于各类矿石中钙镁的检测。
        The sample was decomposed by hydrochloric acid,nitric acid,hydrofluoric acid and perchloric acid,and at pH=6-9,Fe,Al,Cr,Ti,Ag,Hg,Bi,Ni,Co,Pb,Zn,Cu,Cd and Mn were separated by hexamethylenetetramine-copper reagent. Calcium and magnesium were determined by EDTA complexometric titration in ammonia solution of pH =10 and ammonium chloride buffer solution of ammonia chlorideasacid chromium blue K-naphthol green Bas indicator;orcalcium was determined by EDTA complexometric titration in potassium hydroxide solution with calcium reagent as indicator.The content of magnesium or calcium(< 5%)with low content can be accurately determined by ICP-AES when the sample is high in calcium and low in magnesium orhigh inmagnesium and low in calcium.Calcium and magnesium in three standard samples were determined by this method.The results were in agreement with the certified values.The relative standard deviation was between 0.69% and 1.3%(n=7),and the recovery was between 99% and 102%.This method is practical and has been successfully applied to the determination of calcium and magnesium in various ores.
引文
[1]《有色金属工业分析丛书》编辑委员会.重金属冶金分析[M].北京:冶金工业出版社,1994:174-188.
    [2]北京矿冶研究总院测试研究所.有色冶金分析手册[M].北京:冶金工业出版社,2008:210-215.
    [3]北京矿冶研究总院分析室.矿石及有色金属分析手册[M].北京:冶金工业出版社,1990:123-128,234-236,246-247.
    [4]孔凡丽.Na2EDTA滴定法测定复杂高铋物料中铅[J].中国无机分析化学(Chinese Journal of Inorganic Analytical Chemistry),2018,8(4):56-60.
    [5]杨春林,陈潮炎.EDTA络合滴定法测定选铁尾矿中CaF2含量[J].中国无机分析化学(Chinese Journal of Inorganic Analytical Chemistry),2016,6(2):20-24.
    [6]阮桂色.电感耦合等离子体原子发射光谱法(ICP-AES)技术的应用进展[J].中国无机分析化学(Chinese Journal of Inorganic Analytical Chemistry),2011,1(4):15-18.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700