核工业西南物理研究院正在建设的HL-2M托卡马克液氦低温系统中低温用户每周实验需消耗约16m~3液氦,所以设计了一套氦回收纯化系统,此系统包含了回收、储存、纯化三个部分。回收系统由两台流量分别为50m~3/h和100m~3/h高压活塞压缩机组成;储存系统由中高压储罐及气囊组成,最大存储能力6000m~3,其中4800m3高纯氦及1200m~3非高纯氦;纯化系统核心设备为纯化器,纯化器出口的氦气纯度达到99.999%以上。系统建成后最大氦气回收速率为150m~3/h。
The liquid helium cryogenic system(LHCS) is an auxiliary facility of HL-2 M tokamak, which is being built in Southwestern Institute of Physics(SWIP), the demand of liquid helium from cryogenic users are 16 m~3 per week. So it's necessary to construct a helium recovery and purification system(HRPS), which consists of a recovery part, a storage part and a purification part. The recovery part mainly includes 2 piston compressors with capacity 50 m~3/h and 100 m~3/h respectively; the storage part mainly includes 4800 m~3 higher purity helium tanks, 1200 m~3 dirty helium tanks and 50 m~3 two gasbags; the purification system mainly includes a high pressure helium purification equipment, which can improve the helium purity from 95% to 99.999% or even more. The maximum recovery rate of the system is designed to 150 m~3/h.
引文
[1]李少鹏,何昆,桑民敬,等. BEPC2II低温系统的氦气净化技术[J].低温工程,2007,157(3):16-19.
[2]万小刚,傅剑,赵林华.浮空器氦气纯化方法应用研究[J].低温与超导,2012,40(6):4-7.
[3]郭晓虹,金韬,等.超导高电荷态ECR离子源(SECRAL)低温及氦气回收系统[J].中国核科学技术进展报告(第一卷),2009,11:52-55.
[4]袁金辉,白红宇.大型氦低温系统中的杂质净化[J].低温工程,2006(4):28-32.
[5]汪澎,章学华,赵俊.工业废氦气提纯技术探讨[J].低温与超导,2013,41(8):83-88.
[6]陈鑫,朱根良,徐红兵,付猷昆. HL-2M托卡马克装置低温液氦系统的初步设计[J].低温与超导,2015,43(12):22-25.