高效液相色谱法测定可溶微针贴片中维生素C的含量
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Determination of vitamin C in dissolving microneedles by high performance liquid chromatography
  • 作者:赵伟曼 ; 吕慧娟 ; 杨伟汉 ; 董智勇 ; 李莹莹 ; 郑利洁 ; 王清清
  • 英文作者:ZHAO Weiman;Lü Huijuan;YANG Weihan;DONG Zhiyong;LI Yingying;ZHENG Lijie;WANG Qingqing;Department of Pharmaceutics,Faculty of Pharmacy,Bengbu Medical College;
  • 关键词:可溶微针贴片 ; 维生素C ; 高效液相色谱法
  • 英文关键词:dissolving microneedles array;;vitamin C;;HPLC
  • 中文刊名:SXYX
  • 英文刊名:Journal of Shanxi Medical University
  • 机构:蚌埠医学院药学院药物分析教研室;
  • 出版日期:2019-05-14 15:40
  • 出版单位:山西医科大学学报
  • 年:2019
  • 期:v.50;No.319
  • 基金:安徽省自然科学基金资助项目(1608085QH179);; 地方高校国家级大学生创新创业训练计划(201710367040,201810367008,201810367014)
  • 语种:中文;
  • 页:SXYX201905019
  • 页数:4
  • CN:05
  • ISSN:14-1216/R
  • 分类号:104-107
摘要
目的建立高效液相色谱法测定可溶微针贴片中维生素C的含量。方法采用高效液相色谱法,选择Luna C18100A色谱柱(250 mm×4. 6 mm,5μm);流动相为乙腈-水-冰醋酸(10∶89∶1);流速为0. 6 ml/min;柱温为30℃;检测波长为254 nm。考察方法的专属性、线性、精密度、加样回收率、重复性及稳定性。结果维生素C浓度在2. 32-116μg/ml内与HPLC峰面积呈良好的线性关系(Y=88 754X-188 466,R2=0. 999 0),日内精密度的平均RSD值为0. 74%,日间精密度的平均RSD值为0. 56%,平均加样回收率为105. 86%,方法的专属性和重复性良好,供试品溶液24 h内较稳定。结论本研究所建立的高效液相色谱法测定可溶微针贴片中维生素C的含量简便、准确。
        Objective To establish a HPLC method for determining the content of vitamin C in dissolving microneedles array. Methods High performance liquid chromatography was used by Luna C18100 A column( 250 mm × 4. 6 mm,5 μm). Acetonitrile-water-glacial acetic acid( 10 ∶ 89 ∶ 1,V ∶ V ∶ V) was used as the mobile phase. The flow rate was 0. 6 ml/min. The column temperature was 30 ℃ and the detection wavelength was 254 nm. The specificity,linearity,precision,recovery,repeatability and stability of the method were investigated. Results The calibration curve of vitamin C showed good linear relation in the range of 2. 32-116 μg/ml( Y = 88 754 X-188 466,R2= 0. 999 0). The average RSD of intraday precision was 0. 74%,and the average RSD of interday precision was 0. 56%. The average recovery was 105. 86%. The method showed good specificity and repeatability,and the solution was stable in 24 h. Conclusion The established HPLC method for determining the content of vitamin C in dissolving microneedles array is simple and accurate.
引文
[1] Zhu Z,Luo H,Lu W,et al. Rapidly dissolvable microneedle patches for transdermal delivery of exenatide[J]. Pharm Res,2014,31(12):3348-3360.
    [2]王清清,马涛,李见春,等.应用于大分子药物经皮释药的可溶微针贴片制备[J].蚌埠医学院学报,2016,41(4):523-527.
    [3] Matsuo K,Yokota Y,Zhai Y,et al. A low-invasive and effective transcutaneous immunization system using a novel dissolving microneedle array for soluble and particulate antigens[J]. J Control Release,2012,161(1):10-17.
    [4] Arya JM,Dewitt K,Scott Garrard M,et al. Rabies vaccination in dogs using a dissolving microneedle patch[J]. J Control Release,2016,239(10):19-26.
    [5] Wang Q,Yao G,Dong P,et al. Investigation on fabrication process of dissolving microneedle arrays to improve effective needle drug distribution[J]. Eur J Pharm Sci,2015,66(23):148-156.
    [6]刘彬,赵惠新.维生素C含量测定方法综述及其比较[J].课程教育研究,2018,(42):178-179.
    [7]胡霞,陈明龙,杨伟汉,等. HPLC测定可溶微针贴片中熊果苷的含量[J].山西医科大学学报,2018,49(5):498-501.
    [8]国家药典委员会.中国药典2015年版:二部[S].北京:中国医药科技出版社,2015:1237-1238.
    [9]贺澎,王文丽.维生素C片3种含量测定方法的比较[J].中国药品标准,2018,19(2):112-114.
    [10]王奇年. HPLC法测定维生素C注射液中维生素C的含量[J].北方药学,2015,12(9):9-10.