摘要
矿用隔爆兼本质安全型静止无功发生器的研制及应用成功的解决和改善了煤矿井下的供电质量,提高了功率因数,实现了井下就地无功补偿。通过同煤燕子山矿井下SVG线路,功率因数显著提高,末端压降升高,设备启动顺畅,节能降耗明显。
The development and application of mine flame-proof and intrinsically safe static var generator successfully solved and improved the power quality of underground coal mines, improved the power factor, and realized underground reactive compensation. Through the SVG application and measured data of the Yanzishan coal mine, the power factor is significantly improved by the SVG-compensated line, the terminal pressure drop is increased, the equipment starts smoothly, and the energy saving and consumption are obvious.
引文
[1]林渭勋.现代电力电子技术.北京:机械工业出版社,2006.1.
[2]王兆安,杨军,刘进军.谐波抑制和无功功率补偿.北京:机械工业出版社,1998.9.
[3]申爱兵.有源电力滤波器谐波电流检测方法与仿真研究[D].华北电力大学.北京,2006.