摘要
针对储罐不均匀基础沉降造成储罐破坏的问题,为实现对储罐进行不均匀基础沉降监测,研发了基于光纤传感的储罐基础不均匀沉降在线监测技术,能够对储罐基础沉降进行在线监测,量程范围0~100 mm,监测精度达到1 mm,为开展储罐不均匀沉降在线监测系统现场应用提供了良好的技术基础。
Non-uniform foundation settlement of storage tanks is the main reason for the destruction of storage tanks. In order to achieve non-uniform foundation settlement monitoring of storage tanks,astate monitoring technology based on optical fiber sensing was developed. The device could monitor the non-uniform foundation settlement of storage tanks. The measuring range was from 0 mm to 100 mm and the monitoring accuracy was 1 mm. This provided a good technical basis for the on-site application of state monitoring system for non-uniform foundation settlement of storage tanks.
引文
[1]于述强,马红,彭文山.软土地区储罐不均匀沉降分析[J].低温建筑技,2012,34(10):86-88.
[2]杨博文,郑金印.我国国家石油储备基地建设现状[J].中国石油和化工标准与质量,2011,31(05):201+181.
[3]陶彬,张玉平,程庆利,等.全站仪在大型储罐失稳变形评估中的应用[J].安全、健康和环境,2015,15(08):21-24.
[4]程国才,舒安庆,丁克勤.大型储罐不均匀沉降在线监测方法研究[J].化学工程与装备,2017(10):11-13.
[5]谌飞翔.应用光纤传感技术监测大型储罐研究[D].大庆:东北石油大学,2012.
[6]甄永乾,陶彬,张玉平,等.外浮顶储罐浮盘状态监测装置的研发与应用[J].安全、健康和环境,2017,17(07):11-13.