医用电子加速器高能光子水吸收剂量溯源
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Traceability of absorbed dose to water in high-energy photon beams in medical electron accelerators
  • 作者:陆逊 ; 眭国平 ; 杭雪莲 ; 王鹏德 ; 孙荣荣 ; 肖瑶 ; 陈建新 ; 黄军
  • 英文作者:LU Xun;SUI Guoping;HANG Xuelian;WANG Pengde;SUN Rongrong;XIAO Yao;CHEN Jianxin;HUANG Jun;Shanghai Institute of Measurement and Testing Technology;
  • 关键词:高能光子 ; 水吸收剂量 ; 辐射质修正因子 ; 量值传递 ; 量值溯源
  • 英文关键词:High energy photon;;Absorbed dose to water;;Correction factor for beam quality;;Dissemination of the value of quantity;;Traceability of value of quantity
  • 中文刊名:FYFG
  • 英文刊名:Journal of Radiation Research and Radiation Processing
  • 机构:上海市计量测试技术研究院;
  • 出版日期:2017-12-20
  • 出版单位:辐射研究与辐射工艺学报
  • 年:2017
  • 期:v.35
  • 基金:质检公益性行业科研专项:医用加速器光子吸收剂量溯源技术与标准装置研究(201510001-03)~~
  • 语种:中文;
  • 页:FYFG201706008
  • 页数:4
  • CN:06
  • ISSN:31-1258/TL
  • 分类号:52-55
摘要
采用直接法测量医用电子加速器高能光子水吸收剂量,与我国现行的从空气比释动能转化为水吸收剂量间接法测量的结果进行比较。结果表明,两种方法测量结果相差1%以内,同时用传递比较法进行了验证。证明我国基于加速器光子水吸收剂量基准而建设的水吸收剂量溯源体系是可行的,为我国水吸收剂量直接测量提供依据。
        Results obtained by direct measurement of absorbed dose to water for medical electron accelerators were compared with that by indirect measurements(through converting the measured air kerma into absorbed dose to water). Experiments results demonstrate that the difference between two methods is within 1%, it is validated by the transfer comparison method meanwhile. It is demonstrated that the absorbed dose to water traceability system based on the photon absorbed dose to water for the accelerator is feasible. This provides the basis for direct measurement of absorbed dose to water for accelerators.
引文
1全国电离辐射计量技术委员会.JJF1035-2006电离辐射计量术语及定义[S].北京:中国计量出版社,2007.National Ionizing Radiation Metrology Technical Committee.JJF1035-2006 metrological terms and their definitions for ionizing radiation[S].Beijing:China Metrology Publishing House,2007.
    2 全国电离辐射计量技术委员会.JJG589-2008医用电子加速器辐射源检定规程[S].北京:中国计量出版社,2009.National Ionizing Radiation Metrology Technical Committee.JJG589-2008 verification regulation of medical electron accelerator radiation source[S].Beijing:China Metrology Publishing House,2009.
    3 International Atomic Energy Agency.Absorbed dose determination in external beam radiotherapy:an international code of practice for dosimetry based on standards of absorbed dose to water,technical report series No.398[S].Viena,IAEA,2000.
    4 张圆月,杨勇,黄扬,等.医用高能光子水吸收剂量测量规范TRS-277与TRS-398比较[J].中国测试技术,2009,35(2):14-17.ZHANG Yuanyue,YANG yong,HUANG Yang,et al.Comparison between TRS-277 and TRS-398:absorbed dose to water for clinical high-energy photon beams[J].China Measurement&Testing Technology,2009,35(2):14-17.
    5 全国法制计量管理技术委员会.JJF1033-2016计量标准考核规范[S].北京:中国质检出版社,2016.National Legal Metrology Management Technical Committee.JJF1033-2016 rule for the examination of measurement standards[S].Beijing:China Quality Inspection Publishing House,2016.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700