电接点密度继电器存在的主要问题及改进措施
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Main Problems of SF_6 Gas Density Monitor with Magnetic Snap Contact and Countermeasures
  • 作者:习超群 ; 邱曼曼 ; 罗立波 ; 张恩伟 ; 叶慧平 ; 蔡巍 ; 韩相锋 ; 李秀广 ; 金海勇
  • 英文作者:XI Chaoqun;QIU Manman;LUO Libo;ZHANG Enwei;YE Huiping;CAI Wei;HAN Xiangfeng;LI Xiuguang;JIN Haiyong;State Grid Hubei Electric Power Company Maintenance Company UHV AC and DC Inspection Center;State Grid Anhui Electric Power Company Maintenance Company;State Grid Xinjiang Electric Power Company Aletai Power Supply Company;State Grid Jibei Electric Power Company Maintenance Branch Company;State Grid Jiangxi Electric Power Company Ganxi Power Supply Branch Company;Electric Power Research Institute,State Grid Jibei Electric Power Co.,Ltd.;State Grid Ningxia Electric Power Maintenance Company;State Grid Ningxia Electric Power Research Institute;Shanghai Roye Electrical Co.,Ltd.;
  • 关键词:SF6气体密度继电器 ; 电接点 ; 磁助式电接点 ; 漏油
  • 英文关键词:SF6 gas density monitor;;electric contact;;magnetic snap contact;;oil leak
  • 中文刊名:GYDQ
  • 英文刊名:High Voltage Apparatus
  • 机构:国网湖北省电力公司检修公司特高压交直流运检中心;国网安徽省电力公司检修公司;国网新疆电力公司阿勒泰供电公司;国网冀北电力有限公司检修分公司;国网江西省电力公司赣西供电分公司运维检修部;国网冀北电力有限公司电力科学研究院;国网宁夏电力公司检修公司;国网宁夏电力公司电力科学研究院;上海乐研电气有限公司;
  • 出版日期:2017-06-16
  • 出版单位:高压电器
  • 年:2017
  • 期:v.53;No.339
  • 语种:中文;
  • 页:GYDQ201706034
  • 页数:6
  • CN:06
  • ISSN:61-1127/TM
  • 分类号:203-208
摘要
SF_6气体密度继电器作为监测运行设备中SF_6气体密度变化的重要元件,其性能的好坏直接影响着SF_6电气设备的安全运行。文中针对运行中的磁助式电接点的SF_6气体密度继电器接点不能可靠导通以及漏油现象进行分析,找出了原因,并提出了具体的整改措施。经过3年多的现场应用证明其整改措施是非常有效的。
        SF_6 gas density monitor is an important instrument for monitoring SF_6 gas density in electrical equipment,and its performance directly affects safe operation of the SF_6 electrical equipment.In this study,the problems of unreliable conduction of magnetic snap contact and oil leakage were analyzed,the causes were found,and corresponding countermeasures were offered.Execution for three years verified the effectiveness of the countermeasures.
引文
[1]黄烜城,储海军,陈迟,等.SF6密度继电器表的使用状况分析[J].江苏电机工程,2012,31(4):21-23.HU Xuancheng,CHU Haijun,CHEN Chi,et al.Analysi on the use of SF6density monitor table[J].Jiangsu Electrical Engineering,2012(4):21-23.
    [2]贾泽红,陈进,刘健,等.SF6气体密度控制器漏油原因分析及改进意见[J].高压开关,2008,25(4):65-67.JIA Zehong,CHEN Jin,LIU Jian,et al.Leaking caus analysis and improvement suggestion of SF6gas densit switch[J].High Voltage Switchgear,2008,25(4):65-67.
    [3]黄莉.刍议密度继电器漏油及ZDM-5型无油抗震密度继电器[J].中国科技纵横,2010(21):13.HUANG Li.Discussion on the oil leakage of the densit monitor and the ZDM-5 type of the oil resistant seismi density monitor[J].China Science and Technology,2010(21):13.
    [4]张道荣.一起高压断路器爆炸事故的原因及防范措施[J]电力安全技术,2001,3(4):38.ZHANG Daorong.Cause and prevention of a high voltag breaker explosion accident[J].Electrical Safety Technique,2001,3(4):38.
    [5]朱芳菲,孟玉婵,郑铉.SF6气体分析技术[M].北京:兵器工业出版社,1998.ZHU Fangfei,MENG Yuchan,ZHENG Xuan.SF6gas analytic technique[M].Beijing:Weapon Industry Press,1998.
    [6]尹承尚,贺长生.SF6密度继电器现场校验方法的分析[J]高压电器,1996,32(5):23-25.YIN Ch engshang,HE Changsheng.Analysis of SF6densit monitor on-site calibration method[J].High Voltage Apparatus,1996,32(5):23-25.
    [7]DL/T 596-1996电力设备预防性试验规程[S].1996.DL/T 596-1996 Preventive trial of electrical power uni regulation[S].1996.
    [8]DL/T 259-2012六氟化硫气体密度继电器校验规程[S]2012.DL/T 259-2012 Calibration regulation for SF6gas densit monitor[S].2012.
    [9]王润华.SF6气体监测系统在GIS组合电器中的应用[J]上海电力,2006(5):23-25.WANG Runhua.Application of SF6gas monitoring system in GIS combination electric appliance[J].Shanghai Electric Power,2006(5):23-25.
    [10]古玲霞,贺向前,蔡巍,等.一种SF6气体密度继电器全温度范围校验装置的研制[J].高压电器,2015,51(1):127-132.GU Lingxia,HE Xiangqian,CAI Wei,et al.Developmen of a full temperature range calibrator for SF6gas densit monitors[J].High Voltage Apparatus,2015,51(1):127-132.
    [11]李秀广,卢军,吴旭涛,等.SF6电气设备中气体内部微水和密度的在线监测装置的研制[J].高压电器,2015,51(4):72-77.LI Xiuguang,LU Jun,WU Xutao,et al.Development o online monitoring device for SF6gas density and moisture of high voltage apparatus[J].High Voltage Apparatus,2015,51(4):72-77.
    [12]李志刚,蔡巍,邓春,等.SF6气体密度继电器在极端温度下的性能校验[J].中国电力,2012,45(10):73-76.LI Zhigang,CAI Wei,DENG Chun,et al.Calibration o SF6gas density monitors in extremely unusual temperature conditions[J].Electric Power,2012,45(10):73-76.
    [13]青电生技[2002]222号青海省电力公司六氟化硫气体密度继电器检验导则[S].2002.Qinghai Power Corporation[2002]regulation No.222 of SF6density monitor inspection of Qinghai Power Corporation[S].2002.
    [14]福建省电力试验研究院.技术监督简报[J].热工,2004(67):1-3.Fujian Electric Power Testing and Research Institute Technology monitoring bulletin[J].Thermal,2004(67):1-3.
    [15]路自强,李玉海,李红献.SF6气体密度继电器的现场检验[J].青海电力,2004,23(4):22-25.LU Ziqiang,LI Yuhai,LI Hongxian.Field verification o the SF6gas density monitor[J].Qinghai Electric Power,2004,23(4):22-25.
    [16]杨俊宏,李晓彤,畅银萍,等.SF6气体密度控制器的检验[J].高压开关,2009,26(1):68-72.YANG Junhong,LI Xiaotong,CHANG Yinping,et al.Calibration of SF6gas density switch[J].High Voltage Switchgear,2009,26(1):68-72.
    [17]GB/T 22065-2008压力式六氟化硫气体密度控制器[S]2008.GB/T 22065-2008 Pressure type SF6gas density monito[S].2008.
    [18]JB/T 10549-2006气体密度继电器和密度表通用技术条件[S].2006.JB/T 10549-2006 General specification for gas density Monitor and density meter[S].2006.
    [19]路自强.指针式SF6密度控制器示值波动原因分析[J].电工技术,2009(4):67-68.LU Ziqiang.Fluctuation cause analysis of pointer type SF6density switch[J].Electrician Technique,2009(4):67-68.
    [20]田宏亮.SF6密度继电器现场校验的必要性[J].宁夏电力,2010(5):27-28.TIAN Hongliang.The necessity of the scene verification o the SF6density monitor[J].Ningxia Electric Power,2010(5):27-28.
    [21]杨晓东,田进堂,杨涛,等.LW16型SF6断路器密度继电器校验接头改造[J].科学与财富,2010(7):163.YANG Xiaodong,TIAN Jintang YANG Tao,et al.Modification of device for SF6gas density monitor for LW16 type SF6circuit breaker[J].Science and Wealth,2010(7):163.
    [22]生[2012]352号关于印发《国家电网公司十八项电网重大反事故措施》(修订版)[S].2012.National grid of 352(2012)eighteen issued on the issuance of the China State Grid Corp(the major power grid anti accident measures)(Revised Version)[S].2012.
    [23]梅一,孙振兴,齐慧.一起SF6气体密度继电器误动作缺陷的分析[J].安徽电气工程职业技术学院学报,2015,20(5):62-64.MEI Yi,SUN Zhenxing,QI Hui.Analysis of a SF6ga density monitor malfunction defect[J].Journal of Anhu Electrical Engineering Professional Technique College,2015,20(5):62-64.
    [24]吴胜,罗沙,蒲道杰.ZMJ-1型SF6气体密度继电器故障分析[J].安徽电气工程职业技术学院学报,2012,17(1):1-3.WU Sheng,LUO Sha,PU Daojie.Fault analysis of ZMJ-1type SF6gas density monitor[J].Journal of Anhui Electrical Engineering Professional Technique College,2012,17(1):1-3.
    [25]路自强,胡海舰.高海拔对SF6密度继电器及电器设备中SF6充气压力值影响的研究[J].高压电器,2009,45(4):37-40.LU Ziqiang,HU Haijian.High elevation influence on SF6gas density monitor and SF6gas charging pressure of electrical equipment[J].High Voltage Apparatus,2009,45(4):37-40.
    [26]毕玉修.SF6气体密度继电器现场检验的有关问题[J].江苏电机工程,2005,24(5):45-47.BI Yuxiu.Problems of SF6density monitor in field inspection[J].Jiangsu Electrical Engineering,2005,24(5):45-47.
    [27]喻敏,朱立平,王琪,等.SF6气体密度继电器现场检测问题探讨[J].广西电力,2008(4):63-68.YU Min,ZHU Liping,WNAG Qi,et al.Discussion on problems of fidld verification for SF6gas density monito[J].Guangxi Electric Power,2008(4):63-68.