数字化印模在口腔种植中的应用现状
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Current application situation of digital impression technique in oral implantology
  • 作者:林继超 ; 苏恩典 ; 庄怡园 ; 周勇 ; 鄢明东 ; 罗谷声 ; 张雨晴 ; 吴东 ; 陈江
  • 英文作者:LIN Jichao;SU Endian;ZHUANG Yiyuan;ZHOU Yong;YAN Mingdong;LUO Gusheng;ZHANG Yuqing;WU Dong;CHEN Jiang;School of Stomatology,Fujian Medical University;
  • 关键词:口腔种植 ; 数字化印模 ; 传统印模 ; 精确性 ; 适应范围
  • 英文关键词:dental implant;;digital impression;;conventional impression;;accuracy;;indication
  • 中文刊名:KQYX
  • 英文刊名:Stomatology
  • 机构:福建医科大学口腔学院;福建医科大学附属口腔医院口腔种植科;福建医科大学口腔医学院;
  • 出版日期:2019-06-19 15:18
  • 出版单位:口腔医学
  • 年:2019
  • 期:v.39;No.260
  • 语种:中文;
  • 页:KQYX201906014
  • 页数:3
  • CN:06
  • ISSN:32-1255/R
  • 分类号:69-71
摘要
随着数字化技术的进步,口内数字化种植修复印模技术也愈加受到关注。相较于传统印模技术,口内数字化印模技术在时间效率和舒适度方面显示出巨大的优势。然而由于印模的精确性和适用范围的局限,数字化印模技术尚不可完全替代传统印模技术。该文将着重对数字化印模目前应用的局限性进行阐述,希望数字化印模技术能够更加合理地应用于口腔种植学。
        The advent of digital technology leads to the boom of digital impression with intra-oral scanners in implant supported restoration. Compared with the conventional impression, digital impression gives the prospectives advantages of patient comfort as well as time efficiency. However, due to the accuracy and the indication limits of digital impression, it still can not completely replace the conventional impression. This article aims to identify the disadvantages of using digital impression with the hope of the better utility of digital impression in implant therapy.
引文
[1] Iturrate M,Minguez R,Pradies G,et al.Obtaining reliable intraoral digital scans for an implant-supported complete-arch prosthesis:A dental technique[J].J Prosthet Dent,2019,121(2):237-241.
    [2] Paolo P,Francesco P,Paolo S,et al.Precision and accuracy of a digital impression scanner in full-arch implant rehabilitation[J].Int J Prosthodont,2018,31(2):171-175.
    [3] Andriessen FS,Rijkens DR,van der Meer WJ,et al.Applicability and accuracy of an intraoral scanner for scanning multiple implants in edentulous mandibles:A pilot study[J].J Prosthet Dent,2014,111(3):187-193.
    [4] RutkunasV,Mizutani H,Peciuliene V,et al.Maxillary complete denture outcome with two-implant supported mandibular overdentures.A systematic review[J].Stomatologija,2008,10(1):10-15.
    [5] Syrek A,Reich G,Ranftl D,et al.Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling[J].Dent,2010,38(7):553-559.
    [6] Ender A,Zimmermann M,Attin T,et al.In vivo precision of conventional and digital methods for obtaining quadrant dental impressions[J].Clin Oral Invest,2016,20(7):1495-504.
    [7] Alsharbaty MHM,Alikhasi M,Zarrati S,et al.A clinical comparative study of 3-dimensional accuracy between digital and conventional implant impression techniques[J/OL].J Prosthodont,2018 (2018-02-09)[2019-01-20].doi:10.1111/jopr.12764.
    [8] Alikhasi M,Alsharbaty MHM,Moharrami M.Digital implant impression technique accuracy:A systematic review[J].Implant Dent,2017,26(6):929-935.
    [9] Alsharbaty M,Alikhasi M,Zarrati S,et al.A clinical comparative study of 3-dimensional accuracy between digital and conventional implant impression techniques[J/OL].J Prosthodont,(2018-02-09)[2019-02-15].doi:10.1016/j.prosdent.2017.07.002.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700