摘要
选择平行流冷凝器芯体作为Fluent稳态计算模型,对不同的冷凝器流程布置进行仿真分析,以得到冷凝器制冷利侧内流场进出口压降;同时选择冷凝器第一流程的集流管划管作为计算模型,对冷凝器集流管扁管布置进行仿真计算得到制冷利在冷凝器内部的流体相对质量流量E_(?)和流动非均匀度S。计算结果表明,优化后的冷凝器压降为15.83 kPa,比原始方案下降3.12%,而优化后的冷凝器内制冷利非均匀度S也比原始方案降低28.74%。
The parallel flow condenser core is chosen as the Fluent steady calculation model to make simulated analysis for different flow layouts,in order to obtain the pressure drop of internal flow field in condenser.Meanwhile,the group of flat tube and the collecting main in the first process of condenser is chosen to make simulated calculation,further to get the fluid relative mass flow-rate E_i and flow nonuniformity S of the refrigerant of condenser.The calculation results show that the pressure drop of optimized condenser is 15.83kPa, which is 3.12%lower than the original scheme,while the nonuniformity of the refrigerant of optimized condenser is 28.74%lower than the original scheme too.