安徽省游泳馆屋面网架加固分析与处理
详细信息    查看官网全文
摘要
处于潮湿环境中的钢结构网架容易产生锈蚀,而处于酸性腐蚀环境的钢结构网架更容易腐蚀。本文通过对安徽省游泳馆网架的工程案例,依据检测报告中杆件的腐蚀程度扣除其锈蚀壁厚,运用3D3SV12.0软件对锈蚀后的网架进行验算分析,验算结果有773根杆件不够。经过方案比选,选择新增托梁的加固方法,对该网架进行加固设计,并对局部杆件的加固、双球节点之间的连接等难点进行处理,处理的杆件仅有39根,解决了施工的难题,同时对加固后的网架进行安全评估,对今后的类似项目有一定的借鉴意义。
For steel structural grid,it is prone to rust in the damp environment,and it is easier to corrode in the acidic corrosion environment.Through analyzing the project case of grid structure in Anhui natatorium,according to the corrosion degree of bars in the test report,the checking calculation was done by software 3D3SV12.0.It is shown that bearing capacity of 773 bars is insufficient.Comparing a variety of strengthening plans,the one of adding the new trimmer beams is selected to strengthen the grid structure,and technical difficulties of bar strengthening and the connection between the double ball nodes was processed.The researching in this paper has reference significance for similar projects in the future in certain degree.
引文
[1]《建筑结构荷载规范》GB50009-2012,北京:中国建筑工业出版社2012年5月.
    [2]《建筑工程抗震设防分类标准》GB50223-2004,北京:中国建筑工业出版社2004年8月.
    [3]《建筑抗震设计规范》GB50011-2010,北京:中国建筑工业出版社2010年5月.
    [4]《钢结构设计规范》GB50017-2003,北京:中国建筑工业出版社2003年10月.
    [5]《空间网格结构技术规程》JGJ7-2010,北京:中国建筑工业出版社2010年7月.
    [6]《钢结构建筑维护技术规程》DB34/T 1660-2012,安徽:安徽省工程建设标准设计办公室2012年9月.
    [7]沈祖炎.网架与网壳[M].上海:同济大学出版社,1997.
    [8]吴润.平板网架结构的加固分析与设计[J].湖南城市学院学报:自然科学版,2005