核级截止阀外漏原因分析及改进措施
详细信息    查看官网全文
摘要
本文从国内某核电厂热态试验中核一级截止阀密封焊多次外漏问题出发,经综合分析,结果表明阀盖紧固力矩设计值缺失和密封焊质量控制不到位、密封垫片选型不合理是外漏的根本原因。同时介绍了阀门外漏处理方案,为后续机组及其他电厂同类问题提供一定的借鉴。
This paper starts with a problem that the seal welding of the nuclear class one globe vavles leak many times.With a comprehensive analysis of the fundamental reason,the results show that the quality of the valve cover fastening torque value and seal welding quality out of control,the selection of sealing gasket selection not suitable are the fundamental reasons of leakage.At the same time,this paper introduces the valve leakage treatment scheme,and it provides certain reference for the same kind of follow-up units and other plants.
引文
[1]EJ T 1022.6—96.压水堆核电厂阀门焊接与焊缝验收[S].
    [2]0426G4145 B CFC,RCCMI级和RCP系统的截止阀采购要求和清单[S].
    [3]FQX47400012243E04GN A CAE.截止阀竣工文件[S].
    [4]马星.核电站流量仪表管线隔离阀门密封焊泄露原因分析[J],焊接生产应用,2009,8:34-37.
    [5]RCC-M(S焊接篇).压水堆核岛机械设备设计和制造规则2000版+2002补遗[S].
    [6]郭大伟.无垫片焊接密封法兰唇焊结构的泄漏原因及改进[J],化工装备技术,2013,34(3):62-64.
    [7]EJT1022.1—1996—1996.压水堆核电厂阀门制造通则[S].
    [8]低合金高强度钢焊接裂缝问题.[S]哈尔滨焊接研究所,1974.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700